Activity Monitors and Dance-Based Exercise: Estimating Caloric Expenditure
Journal of Dance Medicine & Science · 2002-06 · 6 (2) · 50-53
DOI: 10.1177/1089313x0200600204 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Dance Medicine & Science, online erschienen am 22.03.2023. Verfasst von Shawn P. O'Mailia und 2 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 17 Literaturangaben.
Abstract (Originalsprache)
The purpose of this study was to determine the validity of the Caltrac and Tritrac-R3D activity monitors in predicting the caloric cost of dance based exercise modalities with regard to the CDC 150 kcal criterion. Ten women volunteered to participate in a repeated measures study. The subjects had the following (mean ± SD) characteristics: age: 26.6 ± 8.1 years; weight: 54.8 ± 8.1 kg; height: 162.8 ± 6.3 cm; and VO 2 max: 45.0 ± 3.9 ml-kg -1 .min -1 . All participants performed three 20-minute dance-exercise routines while being measured for predicted energy expenditure with two caloric monitors: The Caltrac and Tritrac-R3D. The subjects were also concurrently measured for actual caloric expenditure with verified laboratory methodology (e.g., open-circuit spirometry). Specifically, the three exercise routines consisted of the following: 1. a “dance style” (DS) step workout, 2. a choreographed “high/low impact” routine (HL), and 3. a repeating and building “high/low impact interval” style “peak performance” (PP) workout. The predicted values of energy expenditure were significantly lower than the actual values (repeated measures ANOVA, p < 0.05). Specifically, the monitors underestimated caloric expenditure by as much as 41% to 52% depending on the particular dance-exercise style. As with many activity monitors, the Caltrac and Tritrac-R3D predict energy cost largely in terms of lower extremity movement/translation. However, in dance-related activities, the upper body and arms provide a great deal of choreographic variety and, as such, are additive to the energy cost delivered by the legs. Therefore, the Caltrac and Tritrac-R3D may not provide appropriate technology for use in accurately determining the energy cost of dance-based exercise modalities or dance performance.
Zitieren
APA
O'Mailia, S. P., Scharff-Olson, M., & Williford, H. N. (2002). Activity Monitors and Dance-Based Exercise: Estimating Caloric Expenditure. Journal of Dance Medicine & Science, 6(2), 50-53. https://doi.org/10.1177/1089313x0200600204
Vancouver
O'Mailia SP, Scharff-Olson M, Williford HN. Activity Monitors and Dance-Based Exercise: Estimating Caloric Expenditure. Journal of Dance Medicine & Science. 2002;6(2):50-53. doi:10.1177/1089313x0200600204
BibTeX
@article{OMailia2002,
author = {O'Mailia, Shawn P. and Scharff-Olson, Michele and Williford, Henry N.},
title = {Activity Monitors and Dance-Based Exercise: Estimating Caloric Expenditure},
journal = {Journal of Dance Medicine & Science},
year = {2002},
volume = {6},
number = {2},
pages = {50--53},
doi = {10.1177/1089313x0200600204}
}
EUVIMED