EUVIMEDEUVIMED entdecken
Crossref

Estimation of Systolic and Diastolic Left Ventricular Blood Flow From Derivatives of Transesophageal Echocardiographic 3D Volume Curves in Cardiac Surgery Patients: A Proof-of-Concept Study

Paul-Michael Jokiel iD, Thilo Schweizer iD, Dominik P Guensch, Denis Berdajs, Joachim Erb, Daniel Bolliger iD, Firmin Kamber, Eckhard Mauermann iD

Seminars in Cardiothoracic and Vascular Anesthesia · 2024

DOI: 10.1177/10892532241286663 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Seminars in Cardiothoracic and Vascular Anesthesia, 2024. Verfasst von Paul-Michael Jokiel und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine, Basel University, Basel, Switzerland. Hauptthemen laut MEDLINE: Echocardiography, Three-Dimensional, Echocardiography, Transesophageal, Cardiac Surgical Procedures, Feasibility Studies. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To examine whether estimates of peak global systolic (S′) and diastolic (E′) left ventricular (LV) flow rates based on 3D echocardiographic volumes are feasible and match physiology.

Methods

In this retrospective feasibility study, we included patients undergoing major cardiac surgery. S′ and E′ were derived from 190 patients by taking the first derivative of the volume-time relationship of 3D ecg-gated transesophageal echocardiography (TEE) images. To examine the quality of images upon which the estimates of flow were based we correlated intraoperative 3D TEE and preoperative 2D transthoracic echocardiography (TTE) volumes. As a proof-of-concept, we then correlated S′ flow with stroke volume and S′ and E′ were compared by valve pathology.

Results

In each of the 190 images, S′ and E′ were derived. There was good correlation between 1) the ejection fraction (EF) of 3D LV images obtained intraoperatively by TEE and preoperatively by TTE (Pearson’s r = 0.65) and also 2) S′ and stroke volume (Pearson’s r = 0.73). Patients with aortic or mitral regurgitation showed higher S′ than patients without valve pathologies (−315 mL/s [95% CI −388 mL/s to −264 mL/s] P = 0.001, −319 mL/s [95% CI −397 mL/s to −246 mL/s] P = 0.001 vs −242 mL/s [95% CI −300 mL/s to −196 mL/s]). These patients also showed higher E′ than patients without valve pathologies (302 mL/s [95% CI 237 mL/s to 384 mL/s] P = 0.006, 341 mL/s [95%CI 227 mL/s to 442 mL/s] P = 0.001 vs 240 mL/s [95%CI 185 mL/s to 315 mL/s]). Patients with aortic stenosis showed no difference in S′ or E’ (−263 mL/s [95%CI −300 mL/s to −212 mL/s] P = 0.793, 255 mL/s [95%CI 188 mL/s to 344 mL/s] P = 0.400).

Conclusions

Estimates of global peak systolic and diastolic LV flow based on 3D TEE are feasible, promising, and match valve pathologies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Echocardiography, Three-DimensionalEchocardiography, TransesophagealCardiac Surgical ProceduresFeasibility StudiesStroke VolumeSystoleHumansRetrospective StudiesMaleFemaleAgedMiddle AgedVentricular Function, LeftProof of Concept StudyDiastoleHeart Ventricles

Stichwörter der Autor:innen

3D echocardiographycardiac outputechocardiographyleft ventricular functionspeckle-trackingvalve pathology

Autor:innen und Institutionen

  • School of Medicine, Basel University, Basel, Switzerland.
  • Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • Division of Cardiac Surgery, Basel University, Basel, Switzerland.
  • Basel University and Clinic for Anesthesia, Intermediate Care, Prehospital Emergency Medicine and Pain Therapy, Basel University Hospital, Basel, Switzerland.
  • Institute of Anesthesiology, Zurich City Hospital, Zurich, Switzerland.

ORCID-Profile: Paul-Michael Jokiel, Thilo Schweizer, Daniel Bolliger, Eckhard Mauermann

Zitieren

APA

Jokiel, P. M., Schweizer, T., Guensch, D. P., Berdajs, D., Erb, J., Bolliger, D., Kamber, F., & Mauermann, E. (2024). Estimation of Systolic and Diastolic Left Ventricular Blood Flow From Derivatives of Transesophageal Echocardiographic 3D Volume Curves in Cardiac Surgery Patients: A Proof-of-Concept Study. Seminars in Cardiothoracic and Vascular Anesthesia. https://doi.org/10.1177/10892532241286663

Vancouver

Jokiel PM, Schweizer T, Guensch DP, Berdajs D, Erb J, Bolliger D, et al. Estimation of Systolic and Diastolic Left Ventricular Blood Flow From Derivatives of Transesophageal Echocardiographic 3D Volume Curves in Cardiac Surgery Patients: A Proof-of-Concept Study. Seminars in Cardiothoracic and Vascular Anesthesia. 2024. doi:10.1177/10892532241286663

BibTeX
@article{Jokiel2024,
  author = {Jokiel, Paul-Michael and Schweizer, Thilo and Guensch, Dominik P and Berdajs, Denis and Erb, Joachim and Bolliger, Daniel and Kamber, Firmin and Mauermann, Eckhard},
  title = {Estimation of Systolic and Diastolic Left Ventricular Blood Flow From Derivatives of Transesophageal Echocardiographic 3D Volume Curves in Cardiac Surgery Patients: A Proof-of-Concept Study},
  journal = {Seminars in Cardiothoracic and Vascular Anesthesia},
  year = {2024},
  doi = {10.1177/10892532241286663}
}
Kostenlos starten →