EUVIMEDEUVIMED entdecken
Crossref

Development and validation of Oncalyx, a digital tool for chemotherapy dose calculation: Content validity, computational accuracy and usability

Ganesh BH, Praneet Singh Bedi, Alim Shaikh, Naureen Imran

Journal of Oncology Pharmacy Practice · 23.11.2026

DOI: 10.1177/10781552261509984 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Oncology Pharmacy Practice, online erschienen am 23.11.2026. Verfasst von Ganesh BH und 3 weiteren Autor:innen. Die Arbeit nennt 37 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Chemotherapy dosing integrates body size, organ function, regimen rules, dose banding and cumulative limits. Manual calculations and unvalidated calculators may introduce errors, while few tools provide transparent calculations tailored to local clinical practice.

Objective

To develop Oncalyx and evaluate its content validity, computational accuracy and usability.

Methods

A web-based, server-side engine incorporated 156 version-controlled rules covering 26 regimens and organ-function adjustments for 25 drugs, derived from guidelines and pivotal trials. Ten oncology professionals (four oncologists, three pharmacists, three nurses) evaluated 21 content-validity items. Independently calculated reference doses for 30 synthetic cases spanning nine clinical profiles (65 drug lines) were compared with Oncalyx outputs at ±1% and ±5% tolerances, using Bland–Altman analysis and Lin's concordance correlation coefficient (CCC). Ninety-two automated test vectors were executed. Usability was evaluated through six observed tasks, the Single Ease Question (SEQ) and System Usability Scale (SUS).

Results

All items achieved item-level content validity indices ≥0.90 (S-CVI/Ave 0.98; S-CVI/UA 0.81); 99.0% of correctness ratings were positive. Body surface area and creatinine clearance agreed within ±1% across all cases. Among 64 evaluable drug lines, 62 (96.9%) agreed within ±1% and 63 (98.4%) within ±5% (bias −0.02%; CCC 0.999). The largest discrepancy (−19.9%) reflected a reference error, not an Oncalyx error. All automated tests passed. Unaided task completion was 98.3%, without critical errors (mean SEQ 6.62/7; SUS 89.0, 95% CI 84.4–93.6).

Conclusions

In this preliminary evaluation, Oncalyx showed excellent content validity, computational agreement and usability. Transparent calculations, unit checks and version-stamped dose sheets facilitate independent verification; larger, multicentre, real-world evaluation is needed before wider use.

Zitieren

APA

BH, G., Bedi, P. S., Shaikh, A., & Imran, N. (2026). Development and validation of Oncalyx, a digital tool for chemotherapy dose calculation: Content validity, computational accuracy and usability. Journal of Oncology Pharmacy Practice. https://doi.org/10.1177/10781552261509984

Vancouver

BH G, Bedi PS, Shaikh A, Imran N. Development and validation of Oncalyx, a digital tool for chemotherapy dose calculation: Content validity, computational accuracy and usability. Journal of Oncology Pharmacy Practice. 2026. doi:10.1177/10781552261509984

BibTeX
@article{BH2026,
  author = {BH, Ganesh and Bedi, Praneet Singh and Shaikh, Alim and Imran, Naureen},
  title = {Development and validation of Oncalyx, a digital tool for chemotherapy dose calculation: Content validity, computational accuracy and usability},
  journal = {Journal of Oncology Pharmacy Practice},
  year = {2026},
  doi = {10.1177/10781552261509984}
}
Kostenlos starten →