Development and feasibility assessment of an in-house gravimetric control system for quality assurance of antineoplastic compounding
Journal of Oncology Pharmacy Practice · 22.07.2026
DOI: 10.1177/10781552261470007 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Oncology Pharmacy Practice, online erschienen am 22.07.2026. Verfasst von Débora Fonseca und 4 weiteren Autor:innen. Beteiligte Einrichtung: Escola Superior de Saúde, Instituto Politécnico do Porto, Rua Dr. António Bernardino de Almeida, 4200-072 Porto, Portugal. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação para a Ciência e Tecnologia and Ministério da Educação, Ciência e Inovação.
Abstract (Originalsprache)
Background
Gravimetric control is an objective quality assurance strategy for detecting compounding errors in antineoplastic preparations. However, implementation remains inconsistent across hospital pharmacies, particularly in resource-limited settings.
Objectives
To develop, and preliminarily assess the feasibility, in a pilot study, of an in-house gravimetric control system for routine quality control of antineoplastic preparations in a hospital chemotherapy compounding unit.
Methods
A descriptive cross-sectional observational study was conducted in a Portuguese hospital between February and March 2024. Antineoplastic preparations compounded in syringes, infusion bags, or pumps were included. Drug densities were determined experimentally using a semi-analytical precision scale. Syringe dead-space-correction was calculated where applicable. A semi-automated Microsoft Excel ® -based gravimetric control system was developed to calculate expected mass and percentage deviation between expected and measured mass. Deviations ≤5% were considered acceptable. Method applicability was assessed in 47 preparations from 11 different drugs.
Results
Density coefficients of variation were consistently low across drugs and container types, supporting measurement precision and solution homogeneity. Differences between measured and dead-space-corrected densities were minimal (mean difference 0.006 g/mL; SD 0.004), indicating negligible practical impact. During applicability testing (n = 47), percentage errors ranged from 0.04% to 2.31%, all within the predefined ±5% acceptance threshold. No preparation required rejection.
Conclusions
In this pilot study, the developed gravimetric control system proved to be practical, affordable, and reliable for routine quality control of chemotherapy preparations. The Excel ® -based gravimetric control system allows rapid implementation without specialized software and may support standardization of compounding verification processes across hospital pharmacies. Wider inter-institutional validation is warranted.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Escola Superior de Saúde, Instituto Politécnico do Porto, Rua Dr. António Bernardino de Almeida, 4200-072 Porto, Portugal.
- Unidade Local de Saúde da Região de Aveiro, Portugal.
- REQUIMTE/LAQV, Escola Superior de Saúde, Instituto Politécnico do Porto, Rua Dr. António Bernardino de Almeida, 4200-072 Porto, Portugal.
ORCID-Profile: Fernando Moreira
Förderung
- Fundação para a Ciência e Tecnologia and Ministério da Educação, Ciência e Inovação
Zitieren
APA
Fonseca, D., Ré, S., Cruz, J. P., Oliveira, A. I., & Moreira, F. (2026). Development and feasibility assessment of an in-house gravimetric control system for quality assurance of antineoplastic compounding. Journal of Oncology Pharmacy Practice. https://doi.org/10.1177/10781552261470007
Vancouver
Fonseca D, Ré S, Cruz JP, Oliveira AI, Moreira F. Development and feasibility assessment of an in-house gravimetric control system for quality assurance of antineoplastic compounding. Journal of Oncology Pharmacy Practice. 2026. doi:10.1177/10781552261470007
BibTeX
@article{Fonseca2026,
author = {Fonseca, Débora and Ré, Susana and Cruz, José Pedro and Oliveira, Ana Isabel and Moreira, Fernando},
title = {Development and feasibility assessment of an in-house gravimetric control system for quality assurance of antineoplastic compounding},
journal = {Journal of Oncology Pharmacy Practice},
year = {2026},
doi = {10.1177/10781552261470007}
}
EUVIMED