EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Development and Internal Validation of an Integrated Clinical, Laboratory, and Ultrasound Model for 30-Day Venous Thromboembolic Deterioration After Acute Lower-Extremity Deep Vein Thrombosis

Cuihua Wang, Haige Zhao, Dandan Guo, Si Zhang, Yafei Yan iD

Clinical and Applied Thrombosis/Hemostasis · 2026-01 · 32

DOI: 10.1177/10760296261508954 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Clinical and Applied Thrombosis/Hemostasis, online erschienen am 17.11.2026. Verfasst von Cuihua Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, Affiliated Hospital of Hebei University, Baoding, Hebei Province, China. Hauptthemen laut MEDLINE: Venous Thrombosis, Venous Thromboembolism, Lower Extremity. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Short-term prognostic tools for venous thromboembolic (VTE) deterioration after acute lower-extremity deep vein thrombosis (DVT) are limited. We aimed to develop and internally validate a model integrating clinical, laboratory, and duplex ultrasound characteristics.

Methods

This single-center retrospective cohort included 785 adults with ultrasound-confirmed acute lower-extremity DVT from January 2018 to December 2025. The primary outcome was clinically detected and objectively confirmed ipsilateral DVT progression or new-onset symptomatic pulmonary embolism (PE) within 30 days. Three nested ridge-penalized logistic models included clinical predictors (Model 1), clinical plus laboratory predictors (Model 2), and clinical, laboratory, and ultrasound predictors (Model 3). Missing data were multiply imputed, and the complete modeling procedure was internally validated with 1,000 bootstrap resamples. Discrimination, calibration, Brier score, incremental performance, and decision-curve net benefit were assessed.

Results

The primary outcome occurred in 102 patients (13.0%): 82 had DVT progression and 27 symptomatic PE, with seven having both. Optimism-corrected AUCs were 0.702, 0.766, and 0.808 (95% CI, 0.769–0.847) for Models 1–3, respectively. For Model 3, the optimism-corrected calibration slope was 0.94 and Brier score 0.087. Optimism-corrected ΔAUCs were 0.064 and 0.042, with corresponding ΔBrier scores of −0.009 and −0.008. Model 3 showed the highest optimism-corrected net benefit across thresholds of approximately 8%–25%. Observed outcome proportions across risk tertiles were 3.1%, 9.6%, and 26.3%.

Conclusions

Model 3 provided internally validated prediction of clinically detected VTE deterioration under local treatment and imaging practices. External validation and prospective clinical-impact assessment are required before routine use.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Venous ThrombosisVenous ThromboembolismLower ExtremityHumansFemaleRetrospective StudiesMaleUltrasonographyMiddle AgedAcute DiseaseAgedPrognosis

Stichwörter der Autor:innen

Deep vein thrombosisDuplex ultrasoundPrediction modelRisk stratificationVenous thromboembolism

Autor:innen und Institutionen

  • Department of Ultrasound, Affiliated Hospital of Hebei University, Baoding, Hebei Province, China.
  • Department of Clinical laboratory, Affiliated Hospital of Hebei University, Baoding, Hebei Province, China.

ORCID-Profile: Yafei Yan

Zitieren

APA

Wang, C., Zhao, H., Guo, D., Zhang, S., & Yan, Y. (2026). Development and Internal Validation of an Integrated Clinical, Laboratory, and Ultrasound Model for 30-Day Venous Thromboembolic Deterioration After Acute Lower-Extremity Deep Vein Thrombosis. Clinical and Applied Thrombosis/Hemostasis, 32. https://doi.org/10.1177/10760296261508954

Vancouver

Wang C, Zhao H, Guo D, Zhang S, Yan Y. Development and Internal Validation of an Integrated Clinical, Laboratory, and Ultrasound Model for 30-Day Venous Thromboembolic Deterioration After Acute Lower-Extremity Deep Vein Thrombosis. Clinical and Applied Thrombosis/Hemostasis. 2026;32. doi:10.1177/10760296261508954

BibTeX
@article{Wang2026,
  author = {Wang, Cuihua and Zhao, Haige and Guo, Dandan and Zhang, Si and Yan, Yafei},
  title = {Development and Internal Validation of an Integrated Clinical, Laboratory, and Ultrasound Model for 30-Day Venous Thromboembolic Deterioration After Acute Lower-Extremity Deep Vein Thrombosis},
  journal = {Clinical and Applied Thrombosis/Hemostasis},
  year = {2026},
  volume = {32},
  doi = {10.1177/10760296261508954}
}
Kostenlos starten →