Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting
Clinical and Applied Thrombosis/Hemostasis · 2023
DOI: 10.1177/10760296231216451 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical and Applied Thrombosis/Hemostasis, 2023. Verfasst von Evelyn Cortina-de-la-Rosa und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Hematology, National Institute of Cardiology Ignacio Chávez, México City, México. Hauptthemen laut MEDLINE: Anticoagulants, Blood Coagulation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Roche Diagnostics International Ltd, Roche Diagnostics Mexico.
Abstract (Originalsprache)
The National Institute of Cardiology has previously used the CoaguChek ® XS Plus system (Roche Diagnostics International Ltd), comparing capillary blood prothrombin time/international normalized ratio (PT/INR) results with those obtained using BCS-XP/Thromborel (Siemens). We assessed the reliability of PT/INR results using the third-generation CoaguChek Pro II system, the CoaguChek XS Plus system, and cobas ® t 411 for citrated plasma analysis. Venous and capillary PT/INR were measured (N = 204). Spearman's correlation, Bland-Altman, and concordance analysis between methods were conducted. Spearman's correlation coefficients between venous/capillary INR were high for CoaguChek Pro II versus CoaguChek XS Plus ( r = 0.994), CoaguChek Pro II versus cobas t 411 ( r = 0.967), and CoaguChek XS Plus versus cobas t 411 ( r = 0.968). Good concordance was observed among capillary methods (concordance coefficient [κ] = 0.888) and remaining relationships ( P < .001 for all): cobas t 411 versus CoaguChek XS Plus (κ = 0.696) and cobas t 411 versus CoaguChek Pro II (κ = 0.684). In conclusion, good agreement was observed between CoaguChek Pro II, CoaguChek XS Plus, and cobas t 411.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Hematology, National Institute of Cardiology Ignacio Chávez, México City, México.
ORCID-Profile: Evelyn Cortina-de-la-Rosa
Förderung
- Roche Diagnostics International Ltd
- Roche Diagnostics Mexico
Zitieren
APA
Cortina-de-la-Rosa, E., Izaguirre-Ávila, R., Ramírez-Hernández, A., Romero-Arroyo, M. O., & Cortés-Cortés, K. (2023). Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting. Clinical and Applied Thrombosis/Hemostasis. https://doi.org/10.1177/10760296231216451
Vancouver
Cortina-de-la-Rosa E, Izaguirre-Ávila R, Ramírez-Hernández A, Romero-Arroyo MO, Cortés-Cortés K. Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting. Clinical and Applied Thrombosis/Hemostasis. 2023. doi:10.1177/10760296231216451
BibTeX
@article{CortinadelaRosa2023,
author = {Cortina-de-la-Rosa, Evelyn and Izaguirre-Ávila, Raúl and Ramírez-Hernández, Alejandro and Romero-Arroyo, María-Oliva and Cortés-Cortés, Karen},
title = {Reliability of International Normalized Ratio Results in the CoaguChek Pro II System in a Clinical Setting},
journal = {Clinical and Applied Thrombosis/Hemostasis},
year = {2023},
doi = {10.1177/10760296231216451}
}
EUVIMED