EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Effects of Fibular Plate Fixation on Ankle Stability in a Weber B Fracture Model With Partial Deltoid Ligament Sectioning

Martin G Gregersen iD, Andreas F Dalen iD, Aleksander L Skrede iD, Øystein Bjelland iD, Fredrik A Nilsen, Marius Molund

Foot & Ankle International · 2024

DOI: 10.1177/10711007241235903 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Foot & Ankle International, 2024. Verfasst von Martin G Gregersen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Medicine and Rehabilitation, Østfold Hospital Trust, Grålum, Norway. Hauptthemen laut MEDLINE: Fibula, Bone Plates, Fracture Fixation, Internal, Joint Instability. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Helse Sør-Øst RHF.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Weber B fractures with concomitant deltoid ligament injury have traditionally been operated with open reduction and internal fixation of the fibular fracture. More recently, clinical studies have suggested that some fractures have concomitant partial deltoid ligament injury with the deep posterior tibiotalar ligament intact (SER4a), allowing for nonoperative treatment in this subgroup. This study explores whether plate fixation of the fibula improves ankle stability in an SER4a injury model. And if so, does it restore native ankle stability?

Methods

Fifteen cadaver ankle specimens were tested in 3 states using an industrial robot: intact joint, SER4a models without plate fixation of the fibula, and SER4a models with plate fixation of the fibula. The robot measured ankle stability in lateral translation, valgus, and internal and external rotation in 3 talocrural joint positions: 10 degrees dorsiflexion, neutral, and 20 degrees plantar flexion. Furthermore, fluoroscopic mortise view radiographs were taken to measure isolated talar shift and talar tilt.

Results

The talar shift and tilt tests showed no differences between the SER4a injury model with and without fibular plate fixation at neutral ankle position with a mean difference of −0.16 mm (95% CI −0.33 to 0.01 mm, P = .071) for talar shift and −0.15 degrees (95% CI −0.01 to 0.30 degrees, P = .068) for talar tilt. However, plate fixation increased external rotation stability, with mean improvements ranging from −7.43 to −9.52 degrees ( P < .001 for all comparisons), but did not restore intact ankle stability. For internal rotation, plate fixation resulted in minor differences.

Conclusion

The results of this suggest that plate fixation of the fibular fracture primarily improves external rotation stability but does not substantially improve lateral translation, valgus, or internal rotation stability in SER4a injury models. In this robotic cadaver model, fibular plate fixation did not fully restore intact ankle stability after simulated SER4a injury. Clinical Relevance: This study offers insights into the effects of fibular plate fixation on Weber B/SER4a injury models and may assist informed decisions when selecting treatments for these types of fractures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FibulaBone PlatesFracture Fixation, InternalJoint InstabilityCadaverLigaments, ArticularAnkle JointHumansAnkle FracturesRange of Motion, ArticularAnkle InjuriesMaleFractures, Bone

Stichwörter der Autor:innen

Weber Bankle fracturebiomechanicsdeltoid ligamentstability assessmenttrauma

Autor:innen und Institutionen

  • Department of Physical Medicine and Rehabilitation, Østfold Hospital Trust, Grålum, Norway.
  • Institute of Health and Society, Faculty of Medicine, University of Oslo, Oslo, Norway.
  • Department of Research and Innovation, Møre and Romsdal Hospital Trust, Ålesund, Norway.
  • Department of Orthopaedic Surgery, Møre and Romsdal Hospital Trust, Ålesund, Norway.
  • Department of ICT and Natural Sciences, Norwegian University of Science and Technology, Ålesund, Norway.
  • Department of Orthopaedic Surgery, Østfold Hospital Trust, Grålum, Norway.

ORCID-Profile: Martin G Gregersen, Andreas F Dalen, Aleksander L Skrede, Øystein Bjelland

Förderung

  • Helse Sør-Øst RHF

Zitieren

APA

Gregersen, M. G., Dalen, A. F., Skrede, A. L., Bjelland, Ø., Nilsen, F. A., & Molund, M. (2024). Effects of Fibular Plate Fixation on Ankle Stability in a Weber B Fracture Model With Partial Deltoid Ligament Sectioning. Foot & Ankle International. https://doi.org/10.1177/10711007241235903

Vancouver

Gregersen MG, Dalen AF, Skrede AL, Bjelland Ø, Nilsen FA, Molund M. Effects of Fibular Plate Fixation on Ankle Stability in a Weber B Fracture Model With Partial Deltoid Ligament Sectioning. Foot & Ankle International. 2024. doi:10.1177/10711007241235903

BibTeX
@article{Gregersen2024,
  author = {Gregersen, Martin G and Dalen, Andreas F and Skrede, Aleksander L and Bjelland, Øystein and Nilsen, Fredrik A and Molund, Marius},
  title = {Effects of Fibular Plate Fixation on Ankle Stability in a Weber B Fracture Model With Partial Deltoid Ligament Sectioning},
  journal = {Foot & Ankle International},
  year = {2024},
  doi = {10.1177/10711007241235903}
}
Kostenlos starten →