EUVIMEDEUVIMED entdecken
Crossref

Shear Wave Tensiometry Can Detect Loading Differences Between Operated and Unaffected Achilles Tendon

Alessandro Schneebeli iD, Marco Barbero, Giuseppe Filardo, Enrique Testa, Martin Riegger, Alessandro Sangiorgio iD, Corrado Cescon, Emiliano Soldini, Deborah Falla

Foot & Ankle International · 2023

DOI: 10.1177/10711007231201156 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Foot & Ankle International, 2023. Verfasst von Alessandro Schneebeli und 8 weiteren Autor:innen. Beteiligte Einrichtung: Centre of Precision Rehabilitation for Spinal Pain (CPR Spine), School of Sport, Exercise and Rehabilitation Sciences, College of Life and Environmen…. Hauptthemen laut MEDLINE: Achilles Tendon, Tendon Injuries. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 39 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The clinically relevant healing process of a ruptured and repaired Achilles tendon (AT) can last more than a year. The purpose of this cross-sectional study was to test if shear wave tensiometry is able to detect AT loading changes between a surgically managed AT rupture versus the unaffected contralateral tendon. Our secondary aims were to evaluate differences in mechanical properties when measured with myotonometry and morphological properties of the tendons measured with ultrasonographic imaging.

Methods

Twenty-one patients with surgically treated AT ruptures were investigated 12-37 months after surgery. Tendon load was measured using a shear wave tensiometer composed of an array of 4 accelerometers fixed on the tendon. Shear wave speed along the Achilles tendon was evaluated at different levels of ankle torque for both the operated and the unaffected side. Mechanical properties of the tendons were evaluated using MyotonPRO and morphological properties using ultrasonographic imaging. Friedman test was used to assess differences in AT wave speed, stiffness, thickness, and cross-sectional area between the operated and the unaffected tendon.

Results

We found a significant shear wave speed difference between sides at every ankle joint torque ( P < .05) with a large effect size for the lowest ankle torque and small to medium effect sizes for higher ankle torque. Stiffness, thickness, and cross-sectional area of the operated tendon remained significantly higher compared to the unaffected side.

Conclusion

In this cohort, we found that shear wave tensiometry can detect differences between operated and unaffected AT during a standardized loading procedure. The shear wave speed along the operated tendon, as well as the mechanical and morphologic properties, remains higher for 1-3 years after a rupture. Level of Evidence: Level III, case-control study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Achilles TendonTendon InjuriesHumansCase-Control StudiesCross-Sectional StudiesAnkleUltrasonographyRupture

Stichwörter der Autor:innen

Achilles tendon ruptureShear wave tensiometry

Autor:innen und Institutionen

  • Centre of Precision Rehabilitation for Spinal Pain (CPR Spine), School of Sport, Exercise and Rehabilitation Sciences, College of Life and Environmental Sciences, University of Birmingham, Birmingham, UK.
  • Rehabilitation Research Laboratory 2rLab, Department of Business Economics, Health and Social Care, University of Applied Sciences and Arts of Southern Switzerland, Manno, Switzerland.
  • Service of Orthopaedics and Traumatology, Department of Surgery, EOC, Lugano, Switzerland.
  • Faculty of Biomedical Sciences, Università della Svizzera Italiana, Lugano, Switzerland.
  • Competence Centre for Healthcare Practices and Policies, Department of Business Economics, Health, and Social Care, University of Applied. Sciences and Arts of Southern Switzerland, Manno, Switzerland.

ORCID-Profile: Alessandro Schneebeli, Alessandro Sangiorgio

Zitieren

APA

Schneebeli, A., Barbero, M., Filardo, G., Testa, E., Riegger, M., Sangiorgio, A., Cescon, C., Soldini, E., & Falla, D. (2023). Shear Wave Tensiometry Can Detect Loading Differences Between Operated and Unaffected Achilles Tendon. Foot & Ankle International. https://doi.org/10.1177/10711007231201156

Vancouver

Schneebeli A, Barbero M, Filardo G, Testa E, Riegger M, Sangiorgio A, et al. Shear Wave Tensiometry Can Detect Loading Differences Between Operated and Unaffected Achilles Tendon. Foot & Ankle International. 2023. doi:10.1177/10711007231201156

BibTeX
@article{Schneebeli2023,
  author = {Schneebeli, Alessandro and Barbero, Marco and Filardo, Giuseppe and Testa, Enrique and Riegger, Martin and Sangiorgio, Alessandro and Cescon, Corrado and Soldini, Emiliano and Falla, Deborah},
  title = {Shear Wave Tensiometry Can Detect Loading Differences Between Operated and Unaffected Achilles Tendon},
  journal = {Foot & Ankle International},
  year = {2023},
  doi = {10.1177/10711007231201156}
}
Kostenlos starten →