EUVIMEDEUVIMED entdecken
Crossref

Incidence of Methemoglobinemia in Cardiothoracic Surgery ICU Patients on Inhaled Nitric Oxide

Tatianna Bourg iD, Carolyn M Bell iD, Jeff McMurray, Jaclyn M Hawn

Annals of Pharmacotherapy · 2026

DOI: 10.1177/10600280251340182 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Pharmacotherapy, 2026. Verfasst von Tatianna Bourg und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmacy, The University of Alabama at Birmingham, Birmingham, AL, USA. Hauptthemen laut MEDLINE: Methemoglobinemia, Nitric Oxide, Cardiac Surgical Procedures, Vasodilator Agents. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Inhaled nitric oxide (iNO) is a selective pulmonary vasodilator utilized for the treatment of right ventricular dysfunction in the cardiac surgery patient population, which carries a risk of developing methemoglobinemia. The actual frequency of methemoglobinemia is not well defined.

Objective

The purpose of this study was to evaluate the incidence of methemoglobinemia in a cardiothoracic surgery intensive care unit (ICU) patient population.

Methods

This was a single-center, retrospective cohort study of 208 cardiothoracic surgery ICU patients who received at least 24 hours of iNO between July 1, 2020 and July 1, 2022. Patients were excluded if they did not have methemoglobin levels collected, received less than 24 hours of iNO therapy, or had documented use of other inhaled vasodilatory therapy during the same admission.

Results

A total of 208 patients were included. Zero patients in this study developed methemoglobinemia. The median duration of iNO therapy was 4 (interquartile range [IQR] = 2.4 to 6.5) days, and the median dose of iNO was 20 (IQR = 20-40) ppm. The median number of methemoglobin levels collected was 3 (IQR = 2-5), with a median methemoglobin level of 1.3% (IQR = 0.9%-1.7 %). Conclusion and Relevance: Our findings suggest that treatment with iNO in adult cardiothoracic surgery ICU patients has a low risk of developing methemoglobinemia. In addition, the outcomes collected provide information regarding iNO use, adverse events, and health care resource use in clinical practice. Routine monitoring of methemoglobin levels may not be necessary for this patient population. Further research is needed to assess the true risk of methemoglobinemia and to establish the appropriate frequency of monitoring in this group.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MethemoglobinemiaNitric OxideCardiac Surgical ProceduresVasodilator AgentsHumansMaleFemaleRetrospective StudiesIntensive Care UnitsMiddle AgedAgedIncidenceAdministration, InhalationCohort Studies

Stichwörter der Autor:innen

cardiothoracic surgerycritical careintensive care unitmethemoglobinmethemoglobinemianitric oxide

Substanzen

Nitric OxideVasodilator Agents

Autor:innen und Institutionen

  • Department of Pharmacy, The University of Alabama at Birmingham, Birmingham, AL, USA.
  • Department of Pharmacy, Medical University of South Carolina, Charleston, SC, USA.
  • Department of Anesthesia, Medical University of South Carolina, Charleston, SC, USA.

ORCID-Profile: Tatianna Bourg, Carolyn M Bell

Zitieren

APA

Bourg, T., Bell, C. M., McMurray, J., & Hawn, J. M. (2026). Incidence of Methemoglobinemia in Cardiothoracic Surgery ICU Patients on Inhaled Nitric Oxide. Annals of Pharmacotherapy. https://doi.org/10.1177/10600280251340182

Vancouver

Bourg T, Bell CM, McMurray J, Hawn JM. Incidence of Methemoglobinemia in Cardiothoracic Surgery ICU Patients on Inhaled Nitric Oxide. Annals of Pharmacotherapy. 2026. doi:10.1177/10600280251340182

BibTeX
@article{Bourg2026,
  author = {Bourg, Tatianna and Bell, Carolyn M and McMurray, Jeff and Hawn, Jaclyn M},
  title = {Incidence of Methemoglobinemia in Cardiothoracic Surgery ICU Patients on Inhaled Nitric Oxide},
  journal = {Annals of Pharmacotherapy},
  year = {2026},
  doi = {10.1177/10600280251340182}
}
Kostenlos starten →