EUVIMEDEUVIMED entdecken
Crossref

The Effect of Albumin Replacement on Vasopressor Duration in Septic Shock in Patients With Hypoalbuminemia

Jacob P Counts iD, Joshua Arnold, Sara Atyia iD, Stella Ogake, Rachel M Smith, Bruce Doepker iD

Annals of Pharmacotherapy · 2024

DOI: 10.1177/10600280241236507 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Pharmacotherapy, 2024. Verfasst von Jacob P Counts und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmacy, Wexner Medical Center, The Ohio State University, Columbus, OH, USA. Hauptthemen laut MEDLINE: Hypoalbuminemia, Shock, Septic, Vasoconstrictor Agents. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The use of albumin resuscitation in septic shock is only recommended in patients who have received large volumes of crystalloid resuscitation regardless of serum albumin concentration. The role of albumin is still largely debated and evidence to support its use still lacking.

Objective

The objective of this study was to evaluate whether albumin replacement increases the number of vasopressor-free days in patients with septic shock and hypoalbuminemia.

Methods

A retrospective analysis was conducted to assess the effect of albumin replacement in septic shock. Hypoalbuminemic patients with septic shock who received albumin were retrospectively compared with a cohort who did not. The primary outcome was number of vasopressor-free days at day 14 from shock presentation, which was analyzed using an adjusted linear regression model to adjust for confounders.

Results

There was no difference in vasopressor-free days at day 14 in patients who received albumin versus those who did not, after adjusting for confounders of exposure (0.50, 95% CI = −0.97 to 1.97; P = 0.502). There also was no difference in secondary outcomes except for need for invasive mechanical ventilation (MV), which was significantly lower in patients who received albumin (61 [54.4%] vs 88 [67.7%]; P = 0.035). Conclusions and Relevance: We observed no difference in vasopressor-free days at day 14 in patients with hypoalbuminemia who received albumin compared with those who did not. However, patients who received albumin required significantly less MV although further studies are warranted to assess this effect.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HypoalbuminemiaShock, SepticVasoconstrictor AgentsHumansMaleFemaleRetrospective StudiesMiddle AgedAgedAlbuminsRespiration, ArtificialFluid Therapy

Stichwörter der Autor:innen

albuminhypoalbuminemiasepsisseptic shock

Substanzen

Vasoconstrictor AgentsAlbumins

Autor:innen und Institutionen

  • Department of Pharmacy, Wexner Medical Center, The Ohio State University, Columbus, OH, USA.
  • Department of Pharmacy, MetroHealth Medical Center, Cleveland, OH, USA.
  • Division of Pulmonary, Critical Care and Sleep Medicine, The Ohio State University Wexner Medical Center, Columbus, OH, USA.
  • The Ohio State University Center for Biostatistics, Columbus, OH, USA.

ORCID-Profile: Jacob P Counts, Sara Atyia, Bruce Doepker

Zitieren

APA

Counts, J. P., Arnold, J., Atyia, S., Ogake, S., Smith, R. M., & Doepker, B. (2024). The Effect of Albumin Replacement on Vasopressor Duration in Septic Shock in Patients With Hypoalbuminemia. Annals of Pharmacotherapy. https://doi.org/10.1177/10600280241236507

Vancouver

Counts JP, Arnold J, Atyia S, Ogake S, Smith RM, Doepker B. The Effect of Albumin Replacement on Vasopressor Duration in Septic Shock in Patients With Hypoalbuminemia. Annals of Pharmacotherapy. 2024. doi:10.1177/10600280241236507

BibTeX
@article{Counts2024,
  author = {Counts, Jacob P and Arnold, Joshua and Atyia, Sara and Ogake, Stella and Smith, Rachel M and Doepker, Bruce},
  title = {The Effect of Albumin Replacement on Vasopressor Duration in Septic Shock in Patients With Hypoalbuminemia},
  journal = {Annals of Pharmacotherapy},
  year = {2024},
  doi = {10.1177/10600280241236507}
}
Kostenlos starten →