EUVIMEDEUVIMED entdecken
Crossref

Integrating fall detection technology in healthcare: A feasibility study of fall sensor usability

Ann Svensson iD, Kristin Schewe Loxley iD, Marit Nygård Olsen, Vebjørn Berre, Arve Opheim

WORK: A Journal of Prevention, Assessment & Rehabilitation · 29.10.2026

DOI: 10.1177/10519815261492234 ↗

Kurz gefasst

Fachartikel in der Zeitschrift WORK: A Journal of Prevention, Assessment & Rehabilitation, online erschienen am 29.10.2026. Verfasst von Ann Svensson und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Business, Economics and IT, University West, Trollhättan, Sweden. Die Arbeit nennt 31 Literaturangaben. Gefördert von: Interreg Sweden-Norway, European Regional Development Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Falls are a significant risk among stroke patients, and effective fall risk assessment and communication between hospital and primary care are essential to prevent adverse events.

Objective

This study evaluates current practices in fall risk assessment and documentation of falls and communication. It also explores the development and pilot testing of a digital fall sensor system to support clinicians in stroke rehabilitation.

Methods

A prospective study of a stroke rehabilitation cohort (n = 31) and an assessed fall risk screening quality and information transfer across care transitions. Concurrently, technical development and laboratory usability testing of a wearable fall sensor were conducted.

Results

Documentation of fall prevention interventions was present in 80% of cases. Only 45% of discharge reports contained relevant fall risk information for primary care providers. The fall sensor during first test detected correctly 12 of 12 fall incidents with unknown false alarm performance. During the second lab test the sensor detected correctly 8 of 12 fall incidents with no false alarms during 10 simulated movements suspected to cause false alarms. Clinical deployment was delayed due to IT infrastructure and regulatory requirements.

Conclusions

There is a critical need to standardize fall risk documentation and improve communication pathways to ensure continuity of care. Laboratory testing demonstrated promising sensor performance, but clinical validation is required before implementation can be recommended.

Schlagwörter

Stichwörter der Autor:innen

accidental fallscontinuity of patient carepatient handoffpreventionquality of healthcarerehabilitationstrokewearable electronic devices

Autor:innen und Institutionen

  • School of Business, Economics and IT, University West, Trollhättan, Sweden.
  • Department of Industrial Management, Industrial Design and Mechanical Engineering, Faculty of Engineering and Sustainable Development, University of Gävle, Gävle, Sweden.
  • Department of Quality and Health Technology, University of Stavanger, Stavanger, Norway.
  • Sunnaas Sykehus HF, Bjørnemyrvegen, Bjørnemyr, Norway.
  • Apertus AS, Ruglandveien, Eiksmarka, Norway.

ORCID-Profile: Ann Svensson, Kristin Schewe Loxley

Förderung

  • Interreg Sweden-Norway, European Regional Development Fund

Zitieren

APA

Svensson, A., Schewe Loxley, K., Nygård Olsen, M., Berre, V., & Opheim, A. (2026). Integrating fall detection technology in healthcare: A feasibility study of fall sensor usability. WORK: A Journal of Prevention, Assessment & Rehabilitation. https://doi.org/10.1177/10519815261492234

Vancouver

Svensson A, Schewe Loxley K, Nygård Olsen M, Berre V, Opheim A. Integrating fall detection technology in healthcare: A feasibility study of fall sensor usability. WORK: A Journal of Prevention, Assessment & Rehabilitation. 2026. doi:10.1177/10519815261492234

BibTeX
@article{Svensson2026,
  author = {Svensson, Ann and Schewe Loxley, Kristin and Nygård Olsen, Marit and Berre, Vebjørn and Opheim, Arve},
  title = {Integrating fall detection technology in healthcare: A feasibility study of fall sensor usability},
  journal = {WORK: A Journal of Prevention, Assessment & Rehabilitation},
  year = {2026},
  doi = {10.1177/10519815261492234}
}
Kostenlos starten →