Normalizing real-time PCR results in routine testing
Journal of Veterinary Diagnostic Investigation · 2024
DOI: 10.1177/10406387231206080 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Veterinary Diagnostic Investigation, 2024. Verfasst von Betsy Armenta-Leyva und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Diagnostic and Production Animal Medicine, College of Veterinary Medicine, Lloyd Veterinary Medical Center, Iowa State Unive…. Hauptthemen laut MEDLINE: Porcine Reproductive and Respiratory Syndrome, Viral Vaccines, Porcine respiratory and reproductive syndrome virus, Swine Diseases. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 70 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: consejo nacional de ciencia y tecnología.
Abstract (Originalsprache)
Normalization, the process of controlling for normal variation in sampling and testing, can be achieved in real-time PCR assays by converting sample quantification cycles (Cqs) to “efficiency standardized Cqs” (ECqs). We calculated ECqs as E −ΔCq , where E is amplification efficiency and ΔCq is the difference between sample and reference standard Cqs. To apply this approach to a commercial porcine reproductive and respiratory syndrome virus (PRRSV) RT-qPCR assay, we created reference standards by rehydrating and then diluting (1 × 10 −4 ) a PRRSV modified-live vaccine (PRRS MLV; Ingelvac) with serum or oral fluid (OF) to match the sample matrix to be tested. Sample ECqs were calculated using the mean E and reference standard Cq calculated from the 4 reference standards on each plate. Serum ( n = 132) and OF ( n = 130) samples were collected from each of 12 pigs vaccinated with a PRRSV MLV from −7 to 42 d post-vaccination, tested, and sample Cqs converted to ECqs. Mean plate Es were 1.75–2.6 for serum and 1.7–2.3 for OF. Mean plate reference standard Cqs were 29.1–31.3 for serum and 29.2–31.5 for OFs. Receiver operating characteristic analysis calculated the area under the curve for serum and OF sample ECqs as 0.999 (95% CI: 0.997, 1.000) and 0.947 (0.890, 1.000), respectively. For serum, diagnostic sensitivity and specificity of the commercial PRRSV RT-qPCR assay were estimated as 97.9% and 100% at an ECq cutoff ≥ 0.20, and for OF, 82.6% and 100%, respectively, at an ECq cutoff ≥ 0.45.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Veterinary Diagnostic and Production Animal Medicine, College of Veterinary Medicine, Lloyd Veterinary Medical Center, Iowa State University, Ames, IA, USA.
- Department of Veterinary Preventive Medicine, College of Veterinary Medicine, the Ohio State University, Columbus, OH, USA.
- Department of Statistics, College of Liberal Arts and Sciences, Iowa State University, Ames, IA, USA.
- Pig Improvement México, Santiago de Querétaro, Querétaro, México.
ORCID-Profile: Betsy Armenta-Leyva, Berenice Munguía-Ramírez, Ting-Yu Cheng, Fangshu Ye, Luis G Giménez-Lirola, Jeffrey Zimmerman
Förderung
- consejo nacional de ciencia y tecnología
Zitieren
APA
Armenta-Leyva, B., Munguía-Ramírez, B., Cheng, T. Y., Ye, F., Henao-Díaz, A., Giménez-Lirola, L. G., & Zimmerman, J. (2024). Normalizing real-time PCR results in routine testing. Journal of Veterinary Diagnostic Investigation. https://doi.org/10.1177/10406387231206080
Vancouver
Armenta-Leyva B, Munguía-Ramírez B, Cheng TY, Ye F, Henao-Díaz A, Giménez-Lirola LG, et al. Normalizing real-time PCR results in routine testing. Journal of Veterinary Diagnostic Investigation. 2024. doi:10.1177/10406387231206080
BibTeX
@article{ArmentaLeyva2024,
author = {Armenta-Leyva, Betsy and Munguía-Ramírez, Berenice and Cheng, Ting-Yu and Ye, Fangshu and Henao-Díaz, Alexandra and Giménez-Lirola, Luis G and Zimmerman, Jeffrey},
title = {Normalizing real-time PCR results in routine testing},
journal = {Journal of Veterinary Diagnostic Investigation},
year = {2024},
doi = {10.1177/10406387231206080}
}
EUVIMED