Robotic-assisted total knee arthroplasty in extra-articular post-traumatic deformities: A case series with one-year outcomes
Journal of Orthopaedic Surgery · 2026-05 · 34 (2)
DOI: 10.1177/10225536261459489 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Orthopaedic Surgery, online erschienen am 09.06.2026. Verfasst von Mariam Zaighum und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Liaquat National Hospital, Karachi, Pakistan. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Osteoarthritis, Knee, Joint Deformities, Acquired. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Purpose
Extra-articular femoral or tibial malunion can distort anatomical landmarks, compromise the reliability of conventional alignment guides, and complicate total knee arthroplasty (TKA). Robotic-assisted TKA (RA-TKA) may improve the precision and reproducibility of bone preparation and component positioning in these anatomically challenging cases. This study reports one-year clinical and radiographic outcomes after single-stage RA-TKA performed without corrective osteotomy in patients with post-traumatic extra-articular deformities.
Methods
This retrospective case series included nine patients (ten knees; one bilateral case) with symptomatic Kellgren–Lawrence grade 4 post-traumatic knee arthritis and associated extra-articular deformity who underwent CT-based RA-TKA using the Robotic Arm Interactive Orthopedic System (RIO; Mako SmartRobotics™, Stryker). Clinical outcomes included Knee Society Score (KSS 2011), Knee Injury and Osteoarthritis Outcome Score (KOOS), visual analogue scale (VAS) pain, and range of motion (ROM) assessed preoperatively and postoperatively at 2 weeks, 6 weeks, 3 months, and 1 year. Radiographic alignment was assessed using Hip–Knee–Ankle (HKA) angle on scanograms and arithmetic hip–knee–ankle angle (aHKA) derived from CT-based planning and intraoperative console values.
Results
Mean HKA improved from 168.3° ± 3.8° preoperatively to 177.7° ± 1.4° postoperatively (mean correction 9.4° ± 2.8° toward neutral). Mean aHKA improved from −4.6° ± 5.0° to −0.6° ± 2.7° (mean correction +4.0°). Mean ROM increased from 95.5° ± 21.7° preoperatively to 119.5° ± 17.4° at 1 year. PROMs improved across timepoints. No major complications, including tracker pin site infection or periprosthetic fracture, were observed.
Conclusion
In selected patients with post-traumatic extra-articular deformity deemed suitable for intra-articular compensation, single-stage RA-TKA without corrective osteotomy achieved consistent coronal alignment correction toward neutral and meaningful improvements in pain, ROM, and patient-reported outcomes at 1 year.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Liaquat National Hospital, Karachi, Pakistan.
- School of Medicine, IMU University, Kuala Lumpur, Malaysia.
- Orthopaedic Centre of Excellence, Sunway Medical Centre, Subang Jaya, Malaysia.
ORCID-Profile: Mariam Zaighum, Patrick Ze-En Ng, Wai Kit Wong, Hwa Sen Chua
Zitieren
APA
Zaighum, M., Ng, P. Z., Wong, W. K., & Chua, H. S. (2026). Robotic-assisted total knee arthroplasty in extra-articular post-traumatic deformities: A case series with one-year outcomes. Journal of Orthopaedic Surgery, 34(2). https://doi.org/10.1177/10225536261459489
Vancouver
Zaighum M, Ng PZ, Wong WK, Chua HS. Robotic-assisted total knee arthroplasty in extra-articular post-traumatic deformities: A case series with one-year outcomes. Journal of Orthopaedic Surgery. 2026;34(2). doi:10.1177/10225536261459489
BibTeX
@article{Zaighum2026,
author = {Zaighum, Mariam and Ng, Patrick Ze-En and Wong, Wai Kit and Chua, Hwa Sen},
title = {Robotic-assisted total knee arthroplasty in extra-articular post-traumatic deformities: A case series with one-year outcomes},
journal = {Journal of Orthopaedic Surgery},
year = {2026},
volume = {34},
number = {2},
doi = {10.1177/10225536261459489}
}
EUVIMED