Comparison of radiolucent CFR-PEEK and titanium volar locking plates in distal radius fracture fixation
Journal of Orthopaedic Surgery · 2026-01 · 34 (1)
DOI: 10.1177/10225536261434069 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Orthopaedic Surgery, online erschienen am 19.03.2026. Verfasst von Tse-Pu Huang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Tri-Service General Hospital, National Defense Medical University, Taipei, Taiwan. Hauptthemen laut MEDLINE: Bone Plates, Titanium, Radius Fractures, Wrist Fractures. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Purpose
Titanium volar locking plates are widely used in distal radius fractures (DFRs) fixation, but their induction of radiographic shielding hinders fracture assessment. Carbon fiber-reinforced polyether ether ketone (CFR-PEEK) plates are radiolucent and biomechanically comparable to titanium, potentially improving intraoperative visualization and postoperative follow-up. This study aims to compare clinical and radiographic outcomes between CFR-PEEK and titanium plates.
Methods
This retrospective study included 39 patients with DRFs treated with either CFR-PEEK ( n = 19) or titanium plates ( n = 20) between August 2018 and June 2019. Intraoperative and postoperative parameters were compared between the two groups. The Wilcoxon rank sum test and Fisher’s exact test were applied for statistical analysis.
Results
Satisfactory fracture reduction without implant-related complications was achieved in both groups. At 12 months, wrist range of motion and radiographic alignment did not significantly differ between the groups (both p > 0.05), and Disabilities of the Arm, Shoulder and Hand (DASH) scores were comparable between the groups (11.8 ± 7.0 vs 11.9 ± 4.6, p > 0.05). Notably, intraoperative CFR-PEEK plates significantly reduced the operative time compared with titanium plates (64.16 ± 15.24 min vs 78.4 ± 20.63 min, p = 0.0387). The implant removal rates did not differ between the groups.
Conclusion
CFR-PEEK volar locking plates demonstrated clinical and radiographic outcomes comparable to titanium plates, with added advantages of radiolucency and surgical efficiency, including a significantly shorter operative time. These findings identify CFR-PEEK plates as a safe and effective alternative in DRFs fixation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, Tri-Service General Hospital, National Defense Medical University, Taipei, Taiwan.
- Department of Orthopedic Surgery, Keelung Branch of Tri-Service General Hospital, National Defense Medical University, Keelung, Taiwan.
- Department of Orthopedic Surgery, Tri-Service General Hospital Penghu Branch, National Defense Medical University, Penghu, Taiwan.
ORCID-Profile: Tse-Pu Huang
Zitieren
APA
Huang, T. P., Zheng, Z. H., Chen, C. Y., Tseng, H. S., Shen, P. H., & Lin, K. Y. (2026). Comparison of radiolucent CFR-PEEK and titanium volar locking plates in distal radius fracture fixation. Journal of Orthopaedic Surgery, 34(1). https://doi.org/10.1177/10225536261434069
Vancouver
Huang TP, Zheng ZH, Chen CY, Tseng HS, Shen PH, Lin KY. Comparison of radiolucent CFR-PEEK and titanium volar locking plates in distal radius fracture fixation. Journal of Orthopaedic Surgery. 2026;34(1). doi:10.1177/10225536261434069
BibTeX
@article{Huang2026,
author = {Huang, Tse-Pu and Zheng, Zhi-Hong and Chen, Chia-Yuan and Tseng, Hui-Sen and Shen, Pei-Hung and Lin, Kun-Yi},
title = {Comparison of radiolucent CFR-PEEK and titanium volar locking plates in distal radius fracture fixation},
journal = {Journal of Orthopaedic Surgery},
year = {2026},
volume = {34},
number = {1},
doi = {10.1177/10225536261434069}
}
EUVIMED