Triple suture fixation for displaced comminuted olecranon fracture with a stable ulnohumeral joint
Journal of Orthopaedic Surgery · 2023
DOI: 10.1177/10225536231215576 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Orthopaedic Surgery, 2023. Verfasst von Suriya Luenam und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Phramongkutklao Hospital and College of Medicine, Bangkok, Thailand. Hauptthemen laut MEDLINE: Olecranon Fracture, Olecranon Process, Elbow Joint, Ulna Fractures. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Purpose
To report the outcome of a novel fixation technique using three high-strength sutures which is including articular buttress suture, cerclage suture, and tension band with off-loading triceps suture (triple suture fixation) in the treatment of displaced comminuted olecranon fracture with a stable ulnohumeral joint (Mayo type IIB). The rationale of using this technique is that the sutures have been used to stabilize multiple fracture fragments in all sides of the olecranon. Material and Methods Between July 2018 and July 2021, 10 patients (7 women, 3 men; mean age, 49.9 years; mean follow-up duration, 27.8 months) with Mayo type IIB olecranon fractures who underwent triple suture fixation were included in the study. The elbow was immobilized in a splint for 2 weeks postoperatively. Range-of-motion exercises were initiated after splint removal and weight bearing was allowed at 6 weeks postoperatively.
Results
Average active range of motion of the elbow was 145° of flexion (range, 135°–150°), 6.5° of extension (range, 0°–30°), 83° of supination (range, 70°–85°), and 77.5° of pronation (range, 70°–80°). Mean MEPS was 98.3 (range, 85–100) and DASH score was 3.1 (range, 0–10) at the final follow-up. Radiographic data at the final follow-up analyzed by paired t test demonstrated that there was no statistically significant difference of proximal olecranon height (OH), trochlear notch width (TW), and OH/TW ratio between postoperative treatment and normal side ( p-value >.05). No complication of implant prominence, fixation failure, nonunion, infection or heterotopic ossification was found postoperatively. Breakage of drill bit occurred during drilling a distal oblique hole for articular buttress suture in one patient.
Conclusion
The triple suture fixation is an effective treatment with low incidence of complications in treatment of Mayo type IIB olecranon fractures. Larger comparative studies are needed to confirm the value of such technique.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics, Phramongkutklao Hospital and College of Medicine, Bangkok, Thailand.
ORCID-Profile: Suriya Luenam
Zitieren
APA
Luenam, S., & Kosiyatrakul, A. (2023). Triple suture fixation for displaced comminuted olecranon fracture with a stable ulnohumeral joint. Journal of Orthopaedic Surgery. https://doi.org/10.1177/10225536231215576
Vancouver
Luenam S, Kosiyatrakul A. Triple suture fixation for displaced comminuted olecranon fracture with a stable ulnohumeral joint. Journal of Orthopaedic Surgery. 2023. doi:10.1177/10225536231215576
BibTeX
@article{Luenam2023,
author = {Luenam, Suriya and Kosiyatrakul, Arkaphat},
title = {Triple suture fixation for displaced comminuted olecranon fracture with a stable ulnohumeral joint},
journal = {Journal of Orthopaedic Surgery},
year = {2023},
doi = {10.1177/10225536231215576}
}
EUVIMED