EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Normative Reference Values for Vibration, Warm and Cold Perception Thresholds in an Indian Population Using the Vibrasense + T Device

Srihari Sharma Kn iD, Sunjyoth Hs iD, Bhajish Bharathan

Annals of Neurosciences · 30.07.2026

DOI: 10.1177/09727531261466876 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Neurosciences, online erschienen am 30.07.2026. Verfasst von Srihari Sharma Kn und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Health Sciences, College of Physiotherapy, Dayananda Sagar University, Bangalore South, Karnataka, India. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Diabetic peripheral neuropathy is a major complication of diabetes and a leading cause of foot ulcers and amputations. Vibrasense + T is a handheld quantitative sensory testing device that integrates vibration, warm and cold perception threshold testing into a single probe.

Purpose

This study aimed to establish normative reference values for Vibrasense + T device in a healthy adult Indian population.

Methods

In this prospective cross-sectional study, 345 healthy adults aged 18–93 years were recruited. Individuals with diabetes, neuropathy or other conditions affecting sensory function were excluded. Vibration perception threshold (VPT), warm perception threshold (WPT) and cold perception threshold (CPT) were assessed bilaterally at standard hand and foot sites using the method of limits. Normative reference values for VPT, WPT and CPT were derived using non-parametric percentile distributions, and the influence of age, sex and anthropometric variables on sensory thresholds was evaluated.

Results

All participants completed testing without adverse events. Sensory thresholds were consistently higher at the foot compared to the hand across all modalities ( p < .001). Age demonstrated a moderate association with VPT and a weaker but significant association with WPT, with thresholds increasing progressively across age groups (all p < .001). In contrast, CPT showed minimal and inconsistent age-related changes. Females exhibited greater sensitivity than males across most modalities. Side-to-side differences were small and not clinically meaningful. Height, weight and BMI did not meaningfully influence sensory thresholds.

Conclusion

This study establishes normative reference values for vibration, warm and cold perception thresholds using the Vibrasense + T device in an Indian population. These age- and sex-stratified values can assist interpretation of sensory thresholds measured with this device in clinical and research settings.

Schlagwörter

Stichwörter der Autor:innen

Quantitative sensory testingcold perception thresholddiabetic peripheral neuropathyperipheral neuropathywarm perception threshold

Autor:innen und Institutionen

  • School of Health Sciences, College of Physiotherapy, Dayananda Sagar University, Bangalore South, Karnataka, India.
  • Medical Affairs, Ayati Devices Pvt. Ltd., Bengaluru, Karnataka, India.

ORCID-Profile: Srihari Sharma Kn, Sunjyoth Hs

Zitieren

APA

Kn, S. S., Hs, S., & Bharathan, B. (2026). Normative Reference Values for Vibration, Warm and Cold Perception Thresholds in an Indian Population Using the Vibrasense + T Device. Annals of Neurosciences. https://doi.org/10.1177/09727531261466876

Vancouver

Kn SS, Hs S, Bharathan B. Normative Reference Values for Vibration, Warm and Cold Perception Thresholds in an Indian Population Using the Vibrasense + T Device. Annals of Neurosciences. 2026. doi:10.1177/09727531261466876

BibTeX
@article{Kn2026,
  author = {Kn, Srihari Sharma and Hs, Sunjyoth and Bharathan, Bhajish},
  title = {Normative Reference Values for Vibration, Warm and Cold Perception Thresholds in an Indian Population Using the Vibrasense + T Device},
  journal = {Annals of Neurosciences},
  year = {2026},
  doi = {10.1177/09727531261466876}
}
Kostenlos starten →