Evaluating the diagnostic accuracy of faecal immunochemical testing in the two-week wait referral pathway for colorectal cancer in the UK
Journal of Medical Screening · 2026
DOI: 10.1177/09691413251347724 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Screening, 2026. Verfasst von Sarala Janarthanan und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK. Hauptthemen laut MEDLINE: Colorectal Neoplasms, Early Detection of Cancer, Occult Blood, Feces. Die Arbeit nennt 23 Literaturangaben.
Abstract (Originalsprache)
Objective
Colorectal cancer (CRC) is the second leading cause of cancer-related mortality in the UK. Early identification and timely intervention rely heavily on the faecal immunohistochemical test (FIT). However, FIT diagnostic accuracy varies, with a sensitivity ranging between 85% and 94% and a noteworthy negative predictive value (NPV) of 99%. The objective of this study was to evaluate the diagnostic accuracy of FIT in detecting CRC and advanced adenomas in patients referred through the 2-week wait (2WW) referral pathway following the National Institute for Health and Care Excellence (NICE) NG12 criteria.
Method
A retrospective analysis was conducted on 1841 patients who were referred through the 2WW pathway. Data on clinical characteristics, FIT test positivity (faecal haemoglobin ≥ 10 µg/g), and subsequent investigations were obtained. The sensitivity, specificity, positive predictive value (PPV), and NPV were calculated based on the presence of adenomas (≥10 mm) or malignancies.
Results
Positive FIT results were observed in 73.4%, negative FIT in 25.9%, and 0.65% of patients lacked FIT availability. The sensitivity, specificity, PPV, and NPV for CRC detection compared to the presence of advanced adenoma or CRC were 96.49% vs. 93.6%, 26.56% vs. 30.2%, 7.31% vs. 21.8%, and 99.18% vs. 95.8%, respectively.
Conclusion
FIT showed the expected performance for CRC detection with an NPV of 99.18%, but a negative FIT result should not exclude investigation with colonoscopy due to a 4.2% likelihood of missing advanced adenomas. There is still a need for other types of testing for CRC screening.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Gastroenterology, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK.
- Department of Colorectal Surgery, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK.
ORCID-Profile: Sarala Janarthanan, Nilanga Nishad, Ciaran Padhiar, Madeleine Frank, Joshua Elias, Bianca Hanganu, Ahlam-Nourelhouda Boussaid Othmani, Dylan McClurg, Irene Jessel, Matthew Denton, Sikandar Khan, Ioanna Panagiotopoulou, Juan De La Revilla Negro, Gareth Corbett
Zitieren
APA
Janarthanan, S., Nishad, N., Padhiar, C., Frank, M., Elias, J., Hanganu, B., Boussaid Othmani, A. N., McClurg, D., Jessel, I., Denton, M., Khan, S., Panagiotopoulou, I., De La Revilla Negro, J., & Corbett, G. (2026). Evaluating the diagnostic accuracy of faecal immunochemical testing in the two-week wait referral pathway for colorectal cancer in the UK. Journal of Medical Screening. https://doi.org/10.1177/09691413251347724
Vancouver
Janarthanan S, Nishad N, Padhiar C, Frank M, Elias J, Hanganu B, et al. Evaluating the diagnostic accuracy of faecal immunochemical testing in the two-week wait referral pathway for colorectal cancer in the UK. Journal of Medical Screening. 2026. doi:10.1177/09691413251347724
BibTeX
@article{Janarthanan2026,
author = {Janarthanan, Sarala and Nishad, Nilanga and Padhiar, Ciaran and Frank, Madeleine and Elias, Joshua and Hanganu, Bianca and Boussaid Othmani, Ahlam-Nourelhouda and McClurg, Dylan and Jessel, Irene and Denton, Matthew and Khan, Sikandar and Panagiotopoulou, Ioanna and De La Revilla Negro, Juan and Corbett, Gareth},
title = {Evaluating the diagnostic accuracy of faecal immunochemical testing in the two-week wait referral pathway for colorectal cancer in the UK},
journal = {Journal of Medical Screening},
year = {2026},
doi = {10.1177/09691413251347724}
}
EUVIMED