EUVIMEDEUVIMED entdecken
Crossref

Case study on inline near infrared measurements of fat in drycured sausages in an industrial setting with minimal factory data

Erik Tengstrand, Katinka Dankel, Karen Wahlstrøm Sanden, Karl Helge Albretsen, Jens Petter Wold

Journal of Near Infrared Spectroscopy · 2026-06 · 34 (3) · 125-135

DOI: 10.1177/09670335261445595 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Near Infrared Spectroscopy, online erschienen am 05.05.2026. Verfasst von Erik Tengstrand und 4 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Gefördert von: Norges ForskningsrÃ¥d.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Deploying a calibration based on near infrared NIR spectroscopy in a factory setting often includes first creating a calibration based on laboratory data and then a calibration based on data from the factory. This has been done in this work, where the aim was to establish in-line monitoring of fat content in drycured sausages directly after the sausage stuffer. The laboratory data was also used to create an industrial calibration, with factory data used for tuning and testing. This approach has the potential to reduce the required factory samples in similar scenarios if the performance of a model based on laboratory data is sufficient. The root mean square error of prediction of the final factory validation set was 0.9% for the laboratory model and 0.8% for the factory model. The calibrated NIR spectroscopy instrument was used in process to monitor the fat variation in the sausages over two periods of 2 days each. The in-line measurements revealed that there was 0.5% variation in fat content between different batches using the same raw materials, and 0.6% variation within batches. The strategy of deploying an in-line NIR spectroscopy instrument gives efficient insight into the process variation and clues about how it can be improved for better raw material utilization and more reliable end-product quality. In this case, there was a factory upgrade between the two measurement trials. The measurements showed that the factory upgrade resulted in a reduction of the standard deviation of the within-batch fat content from 0.60% to 0.32% (after taking the measurement error into account).

Förderung

  • Norges ForskningsrÃ¥d

Zitieren

APA

Tengstrand, E., Dankel, K., Sanden, K. W., Albretsen, K. H., & Wold, J. P. (2026). Case study on inline near infrared measurements of fat in drycured sausages in an industrial setting with minimal factory data. Journal of Near Infrared Spectroscopy, 34(3), 125-135. https://doi.org/10.1177/09670335261445595

Vancouver

Tengstrand E, Dankel K, Sanden KW, Albretsen KH, Wold JP. Case study on inline near infrared measurements of fat in drycured sausages in an industrial setting with minimal factory data. Journal of Near Infrared Spectroscopy. 2026;34(3):125-135. doi:10.1177/09670335261445595

BibTeX
@article{Tengstrand2026,
  author = {Tengstrand, Erik and Dankel, Katinka and Sanden, Karen Wahlstrøm and Albretsen, Karl Helge and Wold, Jens Petter},
  title = {Case study on inline near infrared measurements of fat in drycured sausages in an industrial setting with minimal factory data},
  journal = {Journal of Near Infrared Spectroscopy},
  year = {2026},
  volume = {34},
  number = {3},
  pages = {125--135},
  doi = {10.1177/09670335261445595}
}