Review on Bio-HEA-based orthopedic implants: Stress shielding, elastic modulus, and the role of mathematical modeling
Bio-Medical Materials and Engineering · 03.11.2026
DOI: 10.1177/09592989261503121 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Bio-Medical Materials and Engineering, online erschienen am 03.11.2026. Verfasst von Muhammad Zeeshan und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mathematics, NED University of Engineering and Technology, Karachi, Pakistan. Die Arbeit nennt 44 Literaturangaben.
Abstract (Originalsprache)
Background
Bio-inspired high-entropy alloys (Bio-HEAs) are emerging as materials for orthopedic implants because of their high strength, corrosion resistance, compositional flexibility, and biocompatibility. Their tunable mechanical properties may reduce elastic mismatch with bone and mitigate stress shielding and implant loosening.
Objective
This review evaluates Bio-HEAs for orthopedic applications, emphasizing elastic modulus tailoring, stress-shielding mitigation, microstructural control, biological response, and mathematical modeling.
Methods
Literature on Bio-HEAs for biomedical applications was reviewed, focusing on composition–structure–property relationships, elastic modulus, phase stability, biological response, and computational approaches. Experimental findings were considered alongside molecular dynamics (MD), continuum elasticity, partial differential equation (PDE)-based approaches, and finite element method (FEM) simulations.
Results
Reported Bio-HEAs exhibit elastic moduli ranging approximately from 10 to 30 GPa, providing opportunities to reduce mechanical mismatch with cortical bone. Atomic size mismatch, lattice distortion, phase constitution, and microstructural features influence elastic behavior. MD, continuum models, and FEM provide complementary insights across length scales, while integrated multiscale approaches can improve implant-level predictions and support patient-specific design.
Conclusion
Bio-HEAs offer potential for mechanically compatible orthopedic implants. Integrating materials design with multiscale mathematical modeling may enable improved control of elastic behavior, stress distribution, and implant performance, although experimental validation and clinically relevant modeling are required.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mathematics, NED University of Engineering and Technology, Karachi, Pakistan.
- Computational and Experimental Materials Innovation Group (CEMIG), Department of Metallurgical Engineering, NED University of Engineering and Technology, Karachi, Pakistan.
ORCID-Profile: Muhammad Zeeshan, Muhammad Ali Siddiqui
Zitieren
APA
Zeeshan, M., Siddiqui, M. A., & Baig, M. M. (2026). Review on Bio-HEA-based orthopedic implants: Stress shielding, elastic modulus, and the role of mathematical modeling. Bio-Medical Materials and Engineering. https://doi.org/10.1177/09592989261503121
Vancouver
Zeeshan M, Siddiqui MA, Baig MM. Review on Bio-HEA-based orthopedic implants: Stress shielding, elastic modulus, and the role of mathematical modeling. Bio-Medical Materials and Engineering. 2026. doi:10.1177/09592989261503121
BibTeX
@article{Zeeshan2026,
author = {Zeeshan, Muhammad and Siddiqui, Muhammad Ali and Baig, Mirza Mahmood},
title = {Review on Bio-HEA-based orthopedic implants: Stress shielding, elastic modulus, and the role of mathematical modeling},
journal = {Bio-Medical Materials and Engineering},
year = {2026},
doi = {10.1177/09592989261503121}
}
EUVIMED