A biomechanics-based conceptual design of spring knee-aids to reduce joint loading during high knee-flexion tasks
Bio-Medical Materials and Engineering · 2026-11 · 37 (6) · 303-314
DOI: 10.1177/09592989261487142 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bio-Medical Materials and Engineering, online erschienen am 21.09.2026. Verfasst von John Z Wu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, West Virginia, USA. Hauptthemen laut MEDLINE: Knee Joint, Range of Motion, Articular, Models, Biological. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Intramural CDC HHS, National Institute for Occupational Safety and Health.
Abstract (Originalsprache)
Background
Occupational activities that require high knee-flexion tasks are associated with a higher prevalence of knee osteoarthritis (OA) compared to the general population. Spring knee-aids have been used to protect the knee joints during dynamic high knee-flexion tasks.
Objective
This study was to develop a biomechanical model to analyze the knee joint mechanics during deep squatting while wearing various conceptually designed knee aids.
Methods
The musculoskeletal loadings in the knees were calculated using inverse dynamic modeling. Commercially available software AnyBody (version 7.2) was used for the analysis. In deep squatting, the back of the thighs will contact the calves, influencing the joint contact forces. An analytical approach to consider the effects of the thigh-calf contact interactions was derived and implemented in the AnyBody model. The knee joint loading for deep squatting tasks without knee aids was compared with those wearing knee aids of different spring stiffness levels.
Results
The current biomechanical modeling predictions indicate that the use of typical commercial spring knee-aids helps to reduce the contact forces in the tibiofemoral (TF) and patellofemoral (PF) joints by approximately 7-8%, and that the effects of the knee aids in reducing musculoskeletal loading can be enhanced about four times by increasing the spring stiffness of the knee aids to 1-4 times of the original values.
Conclusion
The current analysis provides a biomechanical basis for improving the design of commercially available knee aids, thereby reducing knee OA in workers frequently performing high knee-flexion tasks.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Morgantown, West Virginia, USA.
- Department of Mechanical Engineering, Northern Illinois University, DeKalb, Illinois, USA.
- Division of Safety Research, National Institute for Occupational Safety and Health, Morgantown, West Virginia, USA.
ORCID-Profile: John Z Wu, Kevin D Moore, Liying Zheng, Ting Xia, Donald R Peterson
Förderung
- Intramural CDC HHS
- National Institute for Occupational Safety and Health
Zitieren
APA
Wu, J. Z., Moore, K. D., Zheng, L., Xia, T., & Peterson, D. R. (2026). A biomechanics-based conceptual design of spring knee-aids to reduce joint loading during high knee-flexion tasks. Bio-Medical Materials and Engineering, 37(6), 303-314. https://doi.org/10.1177/09592989261487142
Vancouver
Wu JZ, Moore KD, Zheng L, Xia T, Peterson DR. A biomechanics-based conceptual design of spring knee-aids to reduce joint loading during high knee-flexion tasks. Bio-Medical Materials and Engineering. 2026;37(6):303-314. doi:10.1177/09592989261487142
BibTeX
@article{Wu2026,
author = {Wu, John Z and Moore, Kevin D and Zheng, Liying and Xia, Ting and Peterson, Donald R},
title = {A biomechanics-based conceptual design of spring knee-aids to reduce joint loading during high knee-flexion tasks},
journal = {Bio-Medical Materials and Engineering},
year = {2026},
volume = {37},
number = {6},
pages = {303--314},
doi = {10.1177/09592989261487142}
}
EUVIMED