Practical evaluation of skin temperature sensors in children during three phases: Clinical differences between contact and infrared methods
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · 2026-08 · 240 (8) · 861-875
DOI: 10.1177/09544119261465864 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, online erschienen am 10.07.2026. Verfasst von Ibtissam Elghailassi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia. Hauptthemen laut MEDLINE: Skin Temperature, Infrared Rays, Thermometers, Thermometry. Die Arbeit nennt 48 Literaturangaben.
Themen: Kinderkrankenpflege
Abstract (Originalsprache)
Selecting skin temperature screening methods is difficult due to the wide variety of measurement techniques and equipment currently available. The hypothesis behind the various skin temperature measurement techniques is that contact methods can change the local skin temperature, whereas non-contact methods are sensitive to environmental elements and require consistent placement. The study aimed to compare contact and non-contact temperature sensors for measuring skin temperature in children’s lower limbs. An experimental study was conducted by utilising NTC thermistors and an infrared thermometer. Seventy children were recruited to participate in this study. Measurements were conducted during three separate trials, which spanned three experimental phases: before, during, and after exercise. The study protocol included 5 min of sitting and resting before the exercise, 5 min of standing in runner’s pose/single-leg march during the exercise, and 5 min of sitting and resting afterwards. Skin temperature data were collected over 20-min intervals for each test. Descriptive statistics and statistical differences among the three tests are illustrated. In three test trials, across all phases, scatter plots consistently revealed a robust, strong correlation between NCTS and CTS readings. NCTS systematically demonstrated higher mean temperature readings when compared to CTS under all conditions. Across all tests and phases, paired samples t-tests revealed that the mean differences between NCTS and CTS were statistically significant ( p < 0.001). The greatest discrepancies and biggest effect sizes were detected in the after-exercise phase, which peaks in Test 3 ( M diff = 2.78°C, ES = 1.46). CTS methods are more reliable and precise for tracking paediatric exercise.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia.
ORCID-Profile: Ibtissam Elghailassi, Nasrul Anuar Abd Razak
Zitieren
APA
Elghailassi, I., Abd Razak, N. A., & Abu Osman, N. A. (2026). Practical evaluation of skin temperature sensors in children during three phases: Clinical differences between contact and infrared methods. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 240(8), 861-875. https://doi.org/10.1177/09544119261465864
Vancouver
Elghailassi I, Abd Razak NA, Abu Osman NA. Practical evaluation of skin temperature sensors in children during three phases: Clinical differences between contact and infrared methods. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2026;240(8):861-875. doi:10.1177/09544119261465864
BibTeX
@article{Elghailassi2026,
author = {Elghailassi, Ibtissam and Abd Razak, Nasrul Anuar and Abu Osman, Noor Azuan},
title = {Practical evaluation of skin temperature sensors in children during three phases: Clinical differences between contact and infrared methods},
journal = {Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine},
year = {2026},
volume = {240},
number = {8},
pages = {861--875},
doi = {10.1177/09544119261465864}
}