Management of comminuted extra-articular distal femoral fracture: A finite element study
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · 2026
DOI: 10.1177/09544119251409453 ↗Kurz gefasst
Fachartikel in der Zeitschrift Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2026. Verfasst von Laureb Rao und 4 weiteren Autor:innen. Beteiligte Einrichtung: Transportation Research and Injury Prevention Centre, Indian Institute of Technology Delhi, New Delhi, India. Hauptthemen laut MEDLINE: Internal Fixators, Fracture Fixation, Internal, Fractures, Comminuted, Femoral Fractures, Distal. Die Arbeit nennt 50 Literaturangaben.
Abstract (Originalsprache)
In case of extra-articular fractures, internal fixation is usually performed using implants such as Intramedullary nails (IMN), medial plates (MP), and lateral plates (LP). Recently, an innovative “sandwich” technique has been introduced for treating acetabular defects. The efficacy of such a technique to treat comminuted extra-articular distal femoral fractures has never been investigated. Therefore, the current study aims to compare the biomechanical performances of three implants, that is, medial plate, lateral plate, and IM nails, with and without the “sandwich” bone grafts. A CAD model of composite bone was used in the study. An extra-articular comminuted distal femoral fracture (2.5 cm) was virtually created in the intact femur using the Materialize 3-matics™ software. The fracture fixation was performed using three implant systems (IMN, MP, and LP) with and without bone graft. A tetrahedral volume mesh was generated, and simulations were performed corresponding to the loading condition of the single leg stance of a person. The use of “sandwich” bone grafts was observed to reduce implant stresses by 4.4%, 57.3%, and 66.2%, and displacements by 17.4%, 56.6%, and 59.7%, in the cases of IMN, MP, and LP, respectively. The Finite Element results showed that the IM nail provided the best results regarding the von Mises distribution, displacement of the implant bone assembly, displacement of the fracture fragments, and contact sliding. Furthermore, the use of Cerament ® -filled bone grafts considerably reduced von Mises stresses in the implants and the displacements of the implant-bone assembly.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Transportation Research and Injury Prevention Centre, Indian Institute of Technology Delhi, New Delhi, India.
- Department of Orthopaedics, Jai Prakash Narayan Apex Trauma Centre, All India Institute of Medical Sciences, New Delhi, India.
- Department of Mechanical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi, Delhi, India.
ORCID-Profile: Laureb Rao
Zitieren
APA
Rao, L., Mittal, S., Trikha, V., Gupta, A., & Mukherjee, K. (2026). Management of comminuted extra-articular distal femoral fracture: A finite element study. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. https://doi.org/10.1177/09544119251409453
Vancouver
Rao L, Mittal S, Trikha V, Gupta A, Mukherjee K. Management of comminuted extra-articular distal femoral fracture: A finite element study. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2026. doi:10.1177/09544119251409453
BibTeX
@article{Rao2026,
author = {Rao, Laureb and Mittal, Samarth and Trikha, Vivek and Gupta, Anupam and Mukherjee, Kaushik},
title = {Management of comminuted extra-articular distal femoral fracture: A finite element study},
journal = {Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine},
year = {2026},
doi = {10.1177/09544119251409453}
}