Optimized starch-iodine method for quantification of sweat volume and pore activation in diabetic neuropathy
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · 2026
DOI: 10.1177/09544119251398453 ↗Kurz gefasst
Fachartikel in der Zeitschrift Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2026. Verfasst von Subathra Yuvaraj und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Rajalakshmi Engineering College, Chennai, Tamil Nadu, India. Hauptthemen laut MEDLINE: Diabetic Neuropathies, Starch, Iodine, Sweat. Die Arbeit nennt 46 Literaturangaben.
Abstract (Originalsprache)
Early detection of Diabetic Neuropathy (DN) relies on quantifying Sweat Glands (SGs) function through non-invasive measures of sweat volume and pore activation. Gravimetry, the most common method, measures sweat mass but cannot assess pore activation and is limited by inter- and intra-patient variability. To address this, an optimized starch-iodine test with a stamper-like mechanism was developed to simultaneously quantify sweat volume and pore activation. An algorithm incorporating Structural Similarity Index Measure (SSIM) and its related correction on estimated volume was employed to enhance measurement accuracy. The study aimed to validate this optimized method against the conventional gravimetry test. Volunteers are recruited across four groups (Control, No DN, DN Stage1, DN Stage2). Both tests were conducted on all participants. DN patients showed significantly reduced sweat volume and pore activation compared to healthy individuals and diabetics without neuropathy. The optimized starch-iodine method demonstrated strong agreement with gravimetry (96.3% accuracy) and showed a significant positive correlation (Spearman’s ρ = 0.846, p < 0.001). Microscopic analysis confirmed progressive structural changes in sweat pores among DN patients, supporting the physiological basis for reduced sweat production. Statistical analysis using one-way Analysis of Variance (ANOVA) revealed that forehead sweat volume ( F = 59.53, p < 0.001), diabetes duration ( F = 182.75, p < 0.001) showed significant differences across groups, indicating their potential utility as distinguishing parameters. Two-way ANOVA confirmed a strong interaction ( F = 331.34, p < 0.001) between forehead sweat and starch-iodine outcomes across groups. By capturing nerve damage through SG activity, this approach enables early and accurate DN diagnosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Rajalakshmi Engineering College, Chennai, Tamil Nadu, India.
ORCID-Profile: Subathra Yuvaraj
Zitieren
APA
Yuvaraj, S., M C, J. C., & Ramakrishnan, K. (2026). Optimized starch-iodine method for quantification of sweat volume and pore activation in diabetic neuropathy. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. https://doi.org/10.1177/09544119251398453
Vancouver
Yuvaraj S, M C JC, Ramakrishnan K. Optimized starch-iodine method for quantification of sweat volume and pore activation in diabetic neuropathy. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2026. doi:10.1177/09544119251398453
BibTeX
@article{Yuvaraj2026,
author = {Yuvaraj, Subathra and M C, Jobin Christ and Ramakrishnan, Kalpana},
title = {Optimized starch-iodine method for quantification of sweat volume and pore activation in diabetic neuropathy},
journal = {Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine},
year = {2026},
doi = {10.1177/09544119251398453}
}
EUVIMED