EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Development and evaluation of a novel 3D in-shoe plantar strain measurement system: STAMPS3D

Francesca Sairally iD, Rory P Turnbull, Heidi J Siddle, David A Russell, Claire Brockett, Peter R Culmer iD

Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · 2025

DOI: 10.1177/09544119251330738 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2025. Verfasst von Francesca Sairally und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, University of Leeds, Leeds, West Yorkshire, UK. Hauptthemen laut MEDLINE: Foot, Stress, Mechanical, Shoes, Imaging, Three-Dimensional. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The formation of diabetic foot ulcers (DFU) is consequential of peripheral neuropathy, peripheral arterial disease and foot deformity, leading to altered foot biomechanics and plantar loads. Plantar load comprises of normal pressure and shear stress, however, there are currently no in-shoe devices capable of measuring both components. The STrain Analysis and Mapping of the Plantar Surface (STAMPS) system, developed at the University of Leeds, utilises Digital Image Correlation (DIC) to measure the strain captured by a plastically deformable insole, as a method to understand plantar load during gait. A 2D DIC software was used to capture cumulative plantar strain and displacement pointwise data, however this method was limited to the analysis of planar surfaces. To address this, 3D instrumentation and DIC methods have been developed and implemented into the STAMPS3D system, used as a tool to capture data that is representative of the non-planar nature of plantar surfaces of the foot. A case-study is used to demonstrate how STAMPS3D can measure multi-dimensional strain, bringing potential to improve clinical screening of DFU risk.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FootStress, MechanicalShoesImaging, Three-DimensionalHumansBiomechanical PhenomenaDiabetic Foot

Stichwörter der Autor:innen

DICDiabetesDigital Image Correlationdiabetic footplantarpressureshearstereostrain

Autor:innen und Institutionen

  • School of Mechanical Engineering, University of Leeds, Leeds, West Yorkshire, UK.
  • Leeds Institute of Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds, West Yorkshire, UK.
  • Leeds Vascular Institute, Leeds Teaching Hospitals NHS Trust, Leeds, West Yorkshire, UK.
  • Leeds Institute of Clinical Trials Research, University of Leeds, Leeds, West Yorkshire, UK.
  • Department of Mechanical Engineering, University of Sheffield, Sheffield, UK.

ORCID-Profile: Francesca Sairally, Peter R Culmer

Zitieren

APA

Sairally, F., Turnbull, R. P., Siddle, H. J., Russell, D. A., Brockett, C., & Culmer, P. R. (2025). Development and evaluation of a novel 3D in-shoe plantar strain measurement system: STAMPS3D. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. https://doi.org/10.1177/09544119251330738

Vancouver

Sairally F, Turnbull RP, Siddle HJ, Russell DA, Brockett C, Culmer PR. Development and evaluation of a novel 3D in-shoe plantar strain measurement system: STAMPS3D. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2025. doi:10.1177/09544119251330738

BibTeX
@article{Sairally2025,
  author = {Sairally, Francesca and Turnbull, Rory P and Siddle, Heidi J and Russell, David A and Brockett, Claire and Culmer, Peter R},
  title = {Development and evaluation of a novel 3D in-shoe plantar strain measurement system: STAMPS3D},
  journal = {Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine},
  year = {2025},
  doi = {10.1177/09544119251330738}
}
Kostenlos starten →