In-vitro external fixation pin-site model proof of concept: A novel approach to studying wound healing in transcutaneous implants
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · 2024
DOI: 10.1177/09544119241234154 ↗Kurz gefasst
Fachartikel in der Zeitschrift Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2024. Verfasst von Blake McCall und 3 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Engineering Research Group, School of Engineering and Applied Science, Aston University, Birmingham, UK. Hauptthemen laut MEDLINE: External Fixators, Fracture Fixation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 68 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Wundversorgung
Abstract (Originalsprache)
External fixation is an essential surgical technique for treating trauma, limb lengthening and deformity correction, however infection is common, with infection rates ranging from 4.5 to 100% of cases. Throughout the literature researchers and clinicians have highlighted a relationship between excessive movement of the pin and skin and an increase in the patient’s risk of infection, however, currently no studies have addressed this role of pin-movement on pin-site wounds. This preliminary study describes a novel in vitro pin-site model, developed using a full-thickness human skin equivalent (HSE) model in conjunction with a bespoke mechanical system which simulates pin-movement. The effect of pin-movement on the wound healing response of the skin equivalents was assessed by measuring the expression of pro-inflammatory cytokines. Six human skin equivalent models were divided into three test groups: no pin as the control, static pin-site wound and dynamic pin-site wound ( n = 3). On day 3 concentrations of IL-1α and IL-8 showed a significant increase compared to the control when a static fixation pin was implanted into the skin equivalent ( p < 0.05) and ( p < 0.005) respectively. Levels of IL-1α and IL-8 increased further in the dynamic sample compared to the static sample ( p < 0.05) and ( p < 0.0005). This study demonstrates for the first time the application of HSE model to study external-fixation pin-movement in vitro. The results of this study demonstrated pin-movement has a negative effect on soft-tissue wound-healing, supporting the anecdotal evidence reported in the literature, however further analysis of wound heading would be required to verify this hypothesis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Biomedical Engineering Research Group, School of Engineering and Applied Science, Aston University, Birmingham, UK.
- Aston Research Centre for Healthy Ageing, School of Life and Health Science, Aston University, Birmingham, UK.
- Aston Institute of Photonics Technology, College of Engineering and Physical Sciences, Aston University, Birmingham, UK.
ORCID-Profile: Blake McCall
Zitieren
APA
McCall, B., Rana, K., Sugden, K., & Junaid, S. (2024). In-vitro external fixation pin-site model proof of concept: A novel approach to studying wound healing in transcutaneous implants. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. https://doi.org/10.1177/09544119241234154
Vancouver
McCall B, Rana K, Sugden K, Junaid S. In-vitro external fixation pin-site model proof of concept: A novel approach to studying wound healing in transcutaneous implants. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 2024. doi:10.1177/09544119241234154
BibTeX
@article{McCall2024,
author = {McCall, Blake and Rana, Karan and Sugden, Kate and Junaid, Sarah},
title = {In-vitro external fixation pin-site model proof of concept: A novel approach to studying wound healing in transcutaneous implants},
journal = {Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine},
year = {2024},
doi = {10.1177/09544119241234154}
}
EUVIMED