EUVIMEDEUVIMED entdecken
Crossref

Safety assessment of onboard high-pressure hydrogen leakage in hydrogen-powered rail vehicles under tunnel conditions

Jian Wu, Yuejuan Li, Changjian Wang, Xuejiao Wang

Proceedings of the Institution of Mechanical Engineers, Part F: Journal of Rail and Rapid Transit · 27.10.2026

DOI: 10.1177/09544097261500810 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Proceedings of the Institution of Mechanical Engineers, Part F: Journal of Rail and Rapid Transit, online erschienen am 27.10.2026. Verfasst von Jian Wu und 3 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To investigate the safety implications of onboard hydrogen leakage in hydrogen-powered rail vehicles under tunnel conditions, this study established a test platform incorporating a full-scale hydrogen storage module and tunnel section, together with high-pressure hydrogen release, concentration and overpressure measurement, and video recording. Six tests, comprising two leakage-only tests and four delayed-ignition tests, examined the blow-down of a single 140 L cylinder initially pressurised to 35 MPa through a manually actuated 5 mm TPRD. The tests were conducted under a fans-off condition and a preset ventilated condition, with the latter corresponding to a fan-controller setting of 50 km/h. A source-term analysis based on the Abel–Noble equation of state and the choked-flow relation gave an initial mass-flow rate of 0.32 kg/s and a choked-flow duration of approximately 56 s. Under the fans-off condition, the highest measured hydrogen concentration was 31.6 vol.% at the sensor above the release region. Clear ignition-related overpressure was recorded at only one of the five pressure sensors, with a maximum of approximately 5.0 kPa; the other sensors showed no response exceeding the approximately ±0.3 kPa baseline fluctuations. Sustained ignition occurred in three of the four delayed-ignition tests; each produced a jet fire, and no deflagration-type pressure signature was identified at the five instrumented pressure locations within the 30 s pressure-recording window. Under the preset ventilated condition, hydrogen was detected at the downstream sensor locations within the instrumented region, and the flame was progressively deflected as the release weakened. These measurements and the documented source-term procedure provide condition-specific engineering information that may inform future ventilation design and hazardous-zone assessment for comparable roof-mounted hydrogen-storage configurations.

Zitieren

APA

Wu, J., Li, Y., Wang, C., & Wang, X. (2026). Safety assessment of onboard high-pressure hydrogen leakage in hydrogen-powered rail vehicles under tunnel conditions. Proceedings of the Institution of Mechanical Engineers, Part F: Journal of Rail and Rapid Transit. https://doi.org/10.1177/09544097261500810

Vancouver

Wu J, Li Y, Wang C, Wang X. Safety assessment of onboard high-pressure hydrogen leakage in hydrogen-powered rail vehicles under tunnel conditions. Proceedings of the Institution of Mechanical Engineers, Part F: Journal of Rail and Rapid Transit. 2026. doi:10.1177/09544097261500810

BibTeX
@article{Wu2026,
  author = {Wu, Jian and Li, Yuejuan and Wang, Changjian and Wang, Xuejiao},
  title = {Safety assessment of onboard high-pressure hydrogen leakage in hydrogen-powered rail vehicles under tunnel conditions},
  journal = {Proceedings of the Institution of Mechanical Engineers, Part F: Journal of Rail and Rapid Transit},
  year = {2026},
  doi = {10.1177/09544097261500810}
}
Kostenlos starten →