Experimental evaluation of heat generation in bone drilling using SS316L and ZrO 2 drill bits across multiple speeds and drill diameters
Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering · 30.06.2026
DOI: 10.1177/09544089261465097 ↗Kurz gefasst
Fachartikel in der Zeitschrift Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering, online erschienen am 30.06.2026. Verfasst von Phanindra Addepalli und 5 weiteren Autor:innen. Die Arbeit nennt 41 Literaturangaben. Gefördert von: Faculty of Engineering, Kasetsart University.
Abstract (Originalsprache)
Overheating of the bone during drilling may raise intraosseous temperature to more than 47°C, leading to osteonecrosis and compromising implant stability. Tool material, geometry and operating conditions play an important role in heat generation. Stainless steel (SS316L) is commonly used, but ZrO 2 has become a possible alternative due to its biocompatibility and lower thermal impact. Custom drill bits (2.5, 3.0 and 3.5 mm diameter; two flutes; 90° point angle; 25° helix angle) were manufactured. A five-axis CNC machine was used to perform drilling experiments on standardized polyurethane bone blocks. A feed rate of 30 mm/min and spindle speeds of 900, 1100 and 1300 r/min were used. Temperatures T max and T avg were measured using thermocouples and recorded in two trials per condition. For T max and T avg , the temperature values obtained in two repeated trials were reported as mean ± standard deviation. SS316L drills produced greater, more fluctuating thermal profiles, reaching a T max of ∼37°C at 900 r/min (2.5 mm) to 58.75°C at 1300 r/min (3.0 mm), exceeding the osteonecrosis threshold. The T avg reached up to 39°C at 1300 r/min. On the contrary, ZrO 2 drills generated lower temperatures with a T max of 31–46°C and a T avg of 29–35°C irrespective of the diameter and speed. It is worth noting that ZrO 2 drills did not surpass 47°C. Thermal response is highly dependent on drill diameter and spindle speed, but material properties are the decisive factor. ZrO 2 drills operated at lower T max and T avg than SS316L and exhibited greater thermal control, minimizing the risk of thermal osteonecrosis. Results suggest that ZrO 2 may provide a safer thermal response during the test dry-bone drilling process.
Förderung
- Faculty of Engineering, Kasetsart University
Zitieren
APA
Addepalli, P., Sawangsri, W., Wattanasinbumrung, P., Ghani, S. A. C., Ibrahim, M. R., & Pukrushpan, J. (2026). Experimental evaluation of heat generation in bone drilling using SS316L and ZrO 2 drill bits across multiple speeds and drill diameters. Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering. https://doi.org/10.1177/09544089261465097
Vancouver
Addepalli P, Sawangsri W, Wattanasinbumrung P, Ghani SAC, Ibrahim MR, Pukrushpan J. Experimental evaluation of heat generation in bone drilling using SS316L and ZrO 2 drill bits across multiple speeds and drill diameters. Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering. 2026. doi:10.1177/09544089261465097
BibTeX
@article{Addepalli2026,
author = {Addepalli, Phanindra and Sawangsri, Worapong and Wattanasinbumrung, Pakanun and Ghani, Saiful Anwar Che and Ibrahim, Mohd Rasidi and Pukrushpan, Jay-Tawee},
title = {Experimental evaluation of heat generation in bone drilling using SS316L and ZrO 2 drill bits across multiple speeds and drill diameters},
journal = {Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering},
year = {2026},
doi = {10.1177/09544089261465097}
}