CFD analysis of the effects of blowing nozzle geometry and angles on air distribution and thermal comfort in wall-type air conditioning systems
Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science · 2026-07 · 240 (14) · 5082-5103
DOI: 10.1177/09544062261436112 ↗Kurz gefasst
Fachartikel in der Zeitschrift Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science, online erschienen am 14.04.2026. Verfasst von Alparslan Şanlı und 2 weiteren Autor:innen. Die Arbeit nennt 43 Literaturangaben.
Abstract (Originalsprache)
The study was conducted to investigate the effects of wall-mounted air conditioning systems on airflow and thermal comfort in enclosed spaces with high thermal loads. Within the scope of numerical analyses, the effect of different air blowing nozzle geometries and blowing angles on air distribution was evaluated using Computational Fluid Dynamics (CFD). Three different air blowing nozzle models were analyzed and compared in terms of airflow, temperature distribution, PMV (Predicted Mean Vote), and PD (Predicted Percentage of Dissatisfied) parameters. For the vertical blowing angle, 60° and 75° were determined to provide the most efficient cooling performance. In the horizontal blowing angle analysis, 67.5° and 75° were found to offer the most favorable conditions in terms of both temperature uniformity and thermal comfort. Additionally, the improved air blowing nozzle geometry, referred to as Model-3, was observed to enhance temperature distribution in the room and lower average temperature values. However, this design produced high PD values in terms of airflow velocity, indicating that certain adjustments are necessary to improve user comfort. The findings obtained from this study are expected to contribute to design evaluations related to airflow management in HVAC systems.
Zitieren
APA
Şanlı, A., Tan, H., & Demircan, T. (2026). CFD analysis of the effects of blowing nozzle geometry and angles on air distribution and thermal comfort in wall-type air conditioning systems. Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science, 240(14), 5082-5103. https://doi.org/10.1177/09544062261436112
Vancouver
Şanlı A, Tan H, Demircan T. CFD analysis of the effects of blowing nozzle geometry and angles on air distribution and thermal comfort in wall-type air conditioning systems. Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science. 2026;240(14):5082-5103. doi:10.1177/09544062261436112
BibTeX
@article{anl2026,
author = {Şanlı, Alparslan and Tan, Hüsamettin and Demircan, Tolga},
title = {CFD analysis of the effects of blowing nozzle geometry and angles on air distribution and thermal comfort in wall-type air conditioning systems},
journal = {Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science},
year = {2026},
volume = {240},
number = {14},
pages = {5082--5103},
doi = {10.1177/09544062261436112}
}