Fachartikel in der Zeitschrift Technology and Health Care, online erschienen am 20.11.2026. Verfasst von Chuxiao Su und 4 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben. Gefördert von: Postdoctoral Fellowship Program of CPSF, China Postdoctoral Science Foundation, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The clinical performance of pulmonary nodule screening systems may be influenced by training data size and differences in imaging characteristics across institutions. Improving model performance and cross-center adaptability is important for clinical deployment.

Objective

To investigate the effects of data expansion and localized fine-tuning on a pulmonary nodule screening system (PNSS) and evaluate its clinical utility for pulmonary nodule detection and classification.

Methods

Lung CT scans from Weifang People's Hospital and Shandong Provincial Hospital were retrospectively analyzed to assess PNSS performance with different training dataset sizes. Localized fine-tuning was further applied to improve cross-center adaptability. A prospective study at Weifang People's Hospital compared PNSS with experienced radiologists in routine clinical practice.

Results

Data expansion increased detection sensitivity from 0.7703 to 0.9428 and classification accuracy from 0.7029 to 0.9486, with performance gains gradually approaching saturation. Localized fine-tuning improved cross-center diagnostic accuracy from 53.57% to 85.36% and sensitivity from 0.5495 to 0.8736. In the prospective evaluation, PNSS achieved a sensitivity of 0.9302 for malignant nodules, 13.95 percentage points higher than radiologists. Overall diagnostic accuracy was 0.92 compared with 0.85 for radiologists. PNSS required only 34 s per case, nearly eight times faster than radiologist review.

Conclusion

Data expansion and localized fine-tuning significantly improved PNSS performance, adaptability, and efficiency, supporting its clinical application in pulmonary nodule screening and early lung cancer detection.

Förderung

  • Postdoctoral Fellowship Program of CPSF
  • China Postdoctoral Science Foundation
  • National Natural Science Foundation of China
  • Fundamental Research Funds for the Central Universities
  • National Key Research and Development Program of China
  • Shandong Provincial Natural Science Foundation

Zitieren

APA

Su, C., Ding, Q., Wang, S., Xia, H., & Fu, Y. (2026). Data expansion and local tuning: A strategy for effective clinical deployment of AI in pulmonary nodule screening. Technology and Health Care. https://doi.org/10.1177/09287329261508375

Vancouver

Su C, Ding Q, Wang S, Xia H, Fu Y. Data expansion and local tuning: A strategy for effective clinical deployment of AI in pulmonary nodule screening. Technology and Health Care. 2026. doi:10.1177/09287329261508375

BibTeX
@article{Su2026,
  author = {Su, Chuxiao and Ding, Qian and Wang, Shaoqiang and Xia, Hui and Fu, Yu},
  title = {Data expansion and local tuning: A strategy for effective clinical deployment of AI in pulmonary nodule screening},
  journal = {Technology and Health Care},
  year = {2026},
  doi = {10.1177/09287329261508375}
}
Kostenlos starten →