Convolutional neural networks for classifying three-phase bone scintigraphy after total knee arthroplasty: A pilot study

Numan Mercan, Ahmet Yurteri, Mustafa Erol, Muhammed Tekin Ertekin

Technology and Health Care · 05.11.2026

DOI: 10.1177/09287329261505428 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Technology and Health Care, online erschienen am 05.11.2026. Verfasst von Numan Mercan und 3 weiteren Autor:innen. Die Arbeit nennt 22 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Total knee arthroplasty (TKA) is increasingly performed, with complications including pain, loosening, and periprosthetic joint infection. When the cause is unclear, three-phase bone scintigraphy (3PBS) is used to assess uptake patterns categorized as normal, aseptic, or septic involvement. We aimed to develop a CNN-based model that classifies phase-wise uptake patterns labeled by a nuclear medicine specialist; side-specific case-level categories were then assigned using a prespecified rule-based algorithm based on the phase outputs. Materials and Methods This retrospective single-center study included 102 patients (81 females, 21 males; mean age 67.0 ± 7.5 years, range 47–84) who underwent 3PBS at least 12 months after TKA (24 right, 25 left, 53 bilateral). Each scan included blood-flow, blood-pool, and delayed phase images labeled. Experiments using five CNN models (ResNet50, VGG11, VGG16, EfficientNet-B0, MobileNet) on phase- and laterality-specific inputs produced low accuracy (33–51%). Therefore, we developed customized CNNs for each phase–laterality combination. Predictions from these models were integrated using a decision algorithm for final side-specific case-level classification.

Results

The customized CNNs achieved 48/49 (98.0%) accuracy in the blood-flow phase, 47/48 (97.9%) in the blood-pool phase, and 50/52 (96.2%) in the delayed phase. Combining phase outputs yielded a side-specific case-level accuracy of 43/47 (91.5%) among test cases with complete three-phase data.

Conclusion

A phase-specific, laterality-aware CNN architecture showed high accuracy in classifying specialist-labeled 3PBS uptake patterns after TKA, with side-specific case-level categories assigned using a prespecified rule-based algorithm based on the phase outputs. These findings are promising but preliminary within this single-center pilot dataset.

Zitieren

APA

Mercan, N., Yurteri, A., Erol, M., & Ertekin, M. T. (2026). Convolutional neural networks for classifying three-phase bone scintigraphy after total knee arthroplasty: A pilot study. Technology and Health Care. https://doi.org/10.1177/09287329261505428

Vancouver

Mercan N, Yurteri A, Erol M, Ertekin MT. Convolutional neural networks for classifying three-phase bone scintigraphy after total knee arthroplasty: A pilot study. Technology and Health Care. 2026. doi:10.1177/09287329261505428

BibTeX
@article{Mercan2026,
  author = {Mercan, Numan and Yurteri, Ahmet and Erol, Mustafa and Ertekin, Muhammed Tekin},
  title = {Convolutional neural networks for classifying three-phase bone scintigraphy after total knee arthroplasty: A pilot study},
  journal = {Technology and Health Care},
  year = {2026},
  doi = {10.1177/09287329261505428}
}