EUVIMEDEUVIMED entdecken
Crossref

Personalized EMG preprocessing and normalization for musculoskeletal simulation

Dovydas Cicėnas, Jurgita Žižienė, Kristina Daunoravičienė

Technology and Health Care · 2026-05 · 34 (3) · 371-391

DOI: 10.1177/09287329261432854 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Technology and Health Care, online erschienen am 25.03.2026. Verfasst von Dovydas Cicėnas und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomechanical Engineering, Faculty of Mechanics, Vilnius Gediminas Technical University, Vilnius, Lithuania. Hauptthemen laut MEDLINE: Electromyography, Muscle, Skeletal, Signal Processing, Computer-Assisted. Die Arbeit nennt 37 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Accurate interpretation of electromyography (EMG) signals is essential for reliable control of musculoskeletal (MS) models in biomechanics and rehabilitation applications. Conventional preprocessing methods may not account for subject-specific signal characteristics and task-related muscle function.

Objective

This study aimed to develop and validate an adaptive and personalized EMG preprocessing pipeline to enhance the physiological accuracy of EMG-driven musculoskeletal models during elbow flexion-extension tasks.

Methods

EMG signals from six upper limb muscles were recorded using a Delsys system while participants performed elbow flexion-extension movements. The signals were preprocessed using individualized spectral filtering and a dual-stage normalization approach. First, dynamic maximum voluntary contraction (MVC) based min–max normalization was applied to standardize signal amplitudes. Second, functional weighting was used to scale each muscle's activation based on its biomechanical contribution to the movement. The processed signals were used as input to an OpenSim elbow model, and resulting joint kinematics were compared to reference motion data captured by an Xsens system.

Results

The EMG-driven OpenSim model showed strong agreement with the Xsens data, with correlation coefficients exceeding 0.98 and root mean square error (RMSE) values below 8°. While a minor systematic offset was observed, joint angle trajectories remained consistent and physiologically plausible across trials.

Conclusion

The proposed subject-specific EMG preprocessing pipeline enhances the accuracy and interpretability of biomechanical models. Future research should explore adaptive signal alignment techniques and AI-based processing methods to improve model robustness in dynamic and wearable scenarios.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectromyographyMuscle, SkeletalSignal Processing, Computer-AssistedHumansBiomechanical PhenomenaMaleMuscle ContractionAdultFemaleComputer SimulationRange of Motion, ArticularYoung AdultElbow Joint

Stichwörter der Autor:innen

EMGOpenSimadaptive filteringmuscle weightingmusculoskeletal simulationsignal normalization

Autor:innen und Institutionen

  • Department of Biomechanical Engineering, Faculty of Mechanics, Vilnius Gediminas Technical University, Vilnius, Lithuania.

Zitieren

APA

Cicėnas, D., Žižienė, J., & Daunoravičienė, K. (2026). Personalized EMG preprocessing and normalization for musculoskeletal simulation. Technology and Health Care, 34(3), 371-391. https://doi.org/10.1177/09287329261432854

Vancouver

Cicėnas D, Žižienė J, Daunoravičienė K. Personalized EMG preprocessing and normalization for musculoskeletal simulation. Technology and Health Care. 2026;34(3):371-391. doi:10.1177/09287329261432854

BibTeX
@article{Cicnas2026,
  author = {Cicėnas, Dovydas and Žižienė, Jurgita and Daunoravičienė, Kristina},
  title = {Personalized EMG preprocessing and normalization for musculoskeletal simulation},
  journal = {Technology and Health Care},
  year = {2026},
  volume = {34},
  number = {3},
  pages = {371--391},
  doi = {10.1177/09287329261432854}
}
Kostenlos starten →