EUVIMEDEUVIMED entdecken
Crossref

Interpreting Cortrak™ feeding tube position: Safety assessment of manufacturer training guides

Stephen J Taylor iD, Kaylee R Sayer, Jules Brown

International Journal of Risk & Safety in Medicine · 2026-02 · 37 (1) · 67-77

DOI: 10.1177/09246479251377592 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Risk & Safety in Medicine, online erschienen am 23.09.2025. Verfasst von Stephen J Taylor und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nutrition and Dietetics, Southmead Hospital Bristol, Bristol, UK. Hauptthemen laut MEDLINE: Intubation, Gastrointestinal, Enteral Nutrition. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Expert Cortrak™ guided-tube placement attains near-zero pneumothorax risk versus 0.52% in ‘blind’ tube placement. Conversely, in low-use Cortrak centres, insufficient training and misinterpretation results in undetected lung misplacement and pneumothorax in 0.10% versus 0.013% for blind placement.

Objective

Determine whether manufacturer training guides enable safe interpretation of tube position.

Methods

Manufacturer guidance was compared to the evidence-based lung-oesophagus, gastrointestinal flexure system (LOGIFS). Manufacturer text and figures were analysed to determine whether it is possible to objectively interpret tube position by organ or its position within an organ.

Results

Manufacturer descriptions are subjective, precluding definitive interpretation of tube position: 1. Lung: No information on the trace angle and distance of deviation from the sagittal midline or receiver or expected trace pattern to warn of misplacement; 2: Stomach: Gastric flexures are not described therefore a tube’s entry, safe position and exit are unknown; 3. Intestine: Manufacturer terms cannot differentiate tube passage into the intestine from retroflexion back to the stomach. Failure to describe the superior- and inferior-duodenal or duodeno-jejunal (DJ) flexures means that intestinal position is not known. Guides only partially describe artefact traces caused by receiver misalignment but not how to correct the receiver position based on the trace.

Conclusions

Lack of objective information to interpret traces and correct for artefacts, combined with mandating tube withdrawal, risks misinterpreting tube position and repeated or failed tube placement, respectively. Manufacturer guides should be substituted with published, evidence-based guides.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intubation, GastrointestinalEnteral NutritionHumansPatient SafetyPneumothorax

Stichwörter der Autor:innen

CortrakENvuedirect visionelectromagneticguided tube placementlung misplacementnasogastricnasointestinaloesophageal misplacementpHpneumoniapneumothoraxtubex-ray

Autor:innen und Institutionen

  • Department of Nutrition and Dietetics, Southmead Hospital Bristol, Bristol, UK.
  • Department of Anaesthetics, Southmead Hospital Bristol, Bristol, UK.

ORCID-Profile: Stephen J Taylor

Zitieren

APA

Taylor, S. J., Sayer, K. R., & Brown, J. (2026). Interpreting Cortrak™ feeding tube position: Safety assessment of manufacturer training guides. International Journal of Risk & Safety in Medicine, 37(1), 67-77. https://doi.org/10.1177/09246479251377592

Vancouver

Taylor SJ, Sayer KR, Brown J. Interpreting Cortrak™ feeding tube position: Safety assessment of manufacturer training guides. International Journal of Risk & Safety in Medicine. 2026;37(1):67-77. doi:10.1177/09246479251377592

BibTeX
@article{Taylor2026,
  author = {Taylor, Stephen J and Sayer, Kaylee R and Brown, Jules},
  title = {Interpreting Cortrak™ feeding tube position: Safety assessment of manufacturer training guides},
  journal = {International Journal of Risk & Safety in Medicine},
  year = {2026},
  volume = {37},
  number = {1},
  pages = {67--77},
  doi = {10.1177/09246479251377592}
}
Kostenlos starten →