EUVIMEDEUVIMED entdecken
Validierungsstudie

AI-Aided Triage for GSWH: Validating an Interpretable HCT-Based Mortality Model

Ali Mansour, Jordan Fuhrman, Ronald Alvarado-Dyer, Elena Badillo Goicoechea, Elaine Lo, Farima Fakhri, John Nugent, Harsh Desai, Molly Lawrence, Olga Pasternak, Paramita Das, Peleg Horowitz und 8 weitere

Journal of Neurotrauma · 01.09.2026 · 43 (17-18) · 1433-1442

DOI: 10.1177/08977151261429994 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Journal of Neurotrauma, online erschienen am 10.03.2026. Verfasst von Ali Mansour und 19 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Division of Neurocritical Care, University of Chicago Medical Center, Chicago, Illinois, USA. Hauptthemen laut MEDLINE: Triage, Wounds, Gunshot, Tomography, X-Ray Computed. Die Arbeit nennt 24 Literaturangaben. Gefördert von: Congressionally Directed Medical Research Programs.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Civilian gunshot wounds to the head (GSWH) carry high mortality yet lack standardized, imaging-based triage tools. Because initial noncontrast head computerized tomography (HCT) is universally obtained but not leveraged with validated, rapid, and reproducible methods, we developed and evaluated an interpretable, attention-based multiple-instance learning (MIL) model to predict in-hospital mortality from the initial HCT. In a retrospective cohort at a single level I trauma center (May 1, 2018–October 31, 2023), we included consecutive adults (≥16 years) with GSWH who underwent HCT, excluding those dead on arrival or without HCT. Of 222 patients, 106 (47.8%) survived to discharge and 116 (52.2%) died. We used a stratified random split to create a development set ( n = 168, 75.7%) and an independent test set ( n = 54, 24.3%); the development set was repeatedly partitioned 100 times into training and validation subsets to quantify performance uncertainty, and each of the 100 models was evaluated once on the test set. The MIL algorithm produced a prognostic severity score with case-level interpretability via attention maps. On the independent test set, discrimination for mortality was high (area under the curve: 0.92, 95% CI: 0.87–0.94) with sensitivity 0.88 (95% CI: 0.78–0.97) and specificity 0.87 (95% CI: 0.74–0.96) at the optimal operating point. Attention visualizations consistently highlighted brainstem, deep midline, and ventricular injury in high-mortality predictions, aligning with established high-risk neuroanatomy. These findings demonstrate that an interpretable, HCT-based MIL model can deliver objective, reproducible risk estimates and transparent case-level explanations, supporting early prognostication and imaging-first triage in penetrating brain injury.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TriageWounds, GunshotTomography, X-Ray ComputedHumansRetrospective StudiesFemaleMaleAdultMultiple-Instance Learning AlgorithmsMiddle AgedHospital Mortality

Stichwörter der Autor:innen

machine-learning modelpenetrating traumatic brain injury

Autor:innen und Institutionen

  • Department of Neurology, Division of Neurocritical Care, University of Chicago Medical Center, Chicago, Illinois, USA.
  • Department of Radiology, University of Chicago Medical Center, Chicago, Illinois, USA.
  • Department of Neurology, Neurosciences Intensive Care Unit, University of Oklahoma, Oklahoma City, Oklahoma, USA.
  • Department of Neurology, Neurosciences Intensive Care Unit, University of Cincinnati, Ohio, USA.
  • Department of Neurology, Division of Vascular Neurology, Geisinger Health Systems, Danville, Pennsylvania, USA.
  • Department of Neurological Surgery, University of Chicago Medical Center, Chicago, Illinois, USA.

Förderung

  • Congressionally Directed Medical Research Programs

Zitieren

APA

Mansour, A., Fuhrman, J., Alvarado-Dyer, R., Goicoechea, E. B., Lo, E., Fakhri, F., Nugent, J., Desai, H., Lawrence, M., Pasternak, O., Das, P., Horowitz, P., Sirko, A., Mansour, M., Roth, W., Fan, T., Carroll, E., Lazaridis, C., Goldenberg, F. D., & Giger, M. (2026). AI-Aided Triage for GSWH: Validating an Interpretable HCT-Based Mortality Model. Journal of Neurotrauma, 43(17-18), 1433-1442. https://doi.org/10.1177/08977151261429994

Vancouver

Mansour A, Fuhrman J, Alvarado-Dyer R, Goicoechea EB, Lo E, Fakhri F, et al. AI-Aided Triage for GSWH: Validating an Interpretable HCT-Based Mortality Model. Journal of Neurotrauma. 2026;43(17-18):1433-1442. doi:10.1177/08977151261429994

BibTeX
@article{Mansour2026,
  author = {Mansour, Ali and Fuhrman, Jordan and Alvarado-Dyer, Ronald and Goicoechea, Elena Badillo and Lo, Elaine and Fakhri, Farima and Nugent, John and Desai, Harsh and Lawrence, Molly and Pasternak, Olga and Das, Paramita and Horowitz, Peleg and Sirko, Andrii and Mansour, Michael and Roth, William and Fan, Tracey and Carroll, Elizabeth and Lazaridis, Christos and Goldenberg, Fernando D and Giger, Maryellen},
  title = {AI-Aided Triage for GSWH: Validating an Interpretable HCT-Based Mortality Model},
  journal = {Journal of Neurotrauma},
  year = {2026},
  volume = {43},
  number = {17-18},
  pages = {1433--1442},
  doi = {10.1177/08977151261429994}
}
Kostenlos starten →