EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Relationship between fill volume and transport in peritoneal dialysis—from bench to bedside

Carl M Öberg iD

Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis · 2026-01 · 46 (1) · 32-39

DOI: 10.1177/08968608241290019 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis, online erschienen am 15.10.2024. Verfasst von Carl M Öberg. Beteiligte Einrichtung: Department of Clinical Sciences Lund, Skåne University Hospital, Lund, Sweden. Hauptthemen laut MEDLINE: Peritoneal Dialysis, Dialysis Solutions, Peritoneum. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Crafoordska Stiftelsen, Lund University Medical Faculty Foundation, Swedish Kidney Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Larger fill volumes in peritoneal dialysis (PD) typically improve small solute clearance and water removal, and vice versa —but the relationship between intraperitoneal volume and the capacities for solute and water transport in PD has been little studied. Here, it is proposed that this relative relationship is described by a simple ratio (Volume new /Volume old ) 2/3 up to a critical break-point volume, beyond which further volume increase is less beneficial in terms of solute and water removal.

Method

To scrutinize this hypothesis, experiments were conducted in a rat model of PD alongside a retrospective analysis of data from a prior clinical study. Rats underwent PD with either three consecutive fills of 8 + 8 + 8 mL (n = 10) or 12 + 12 + 12 mL (n = 10), with 45-minute dwell time intervals. This approach yielded 60 estimations of water and solute transport, characterized by osmotic conductance to glucose and solute diffusion capacities, respectively.

Results

Comparative analysis of the predictive efficacy of the two models—the simple ratio versus the break-point model—was performed using Monte Carlo cross-validation. The break-point model emerged as a superior predictor for both water and solute transfer, demonstrating its capability to characterize both experimental data from rats and clinical data from patients.

Conclusion

The present analysis indicates that relatively simple calculations can be used to approximate clinical effects on solute and water removal when prescribing a lower or higher fill volume to patients with PD.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Peritoneal DialysisDialysis SolutionsPeritoneumAnimalsRatsBiological TransportRetrospective StudiesMaleHumansDisease Models, Animal

Stichwörter der Autor:innen

Peritoneal dialysisdiffusion capacity

Substanzen

Dialysis Solutions

Autor:innen und Institutionen

  • Department of Clinical Sciences Lund, Skåne University Hospital, Lund, Sweden.

ORCID-Profile: Carl M Öberg

Förderung

  • Crafoordska Stiftelsen
  • Lund University Medical Faculty Foundation
  • Swedish Kidney Foundation
  • The Inga-Britt and Arne Lundberg’s Research Foundation

Zitieren

APA

Öberg, C. M. (2026). Relationship between fill volume and transport in peritoneal dialysis—from bench to bedside. Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis, 46(1), 32-39. https://doi.org/10.1177/08968608241290019

Vancouver

Öberg CM. Relationship between fill volume and transport in peritoneal dialysis—from bench to bedside. Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis. 2026;46(1):32-39. doi:10.1177/08968608241290019

BibTeX
@article{berg2026,
  author = {Öberg, Carl M},
  title = {Relationship between fill volume and transport in peritoneal dialysis—from bench to bedside},
  journal = {Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis},
  year = {2026},
  volume = {46},
  number = {1},
  pages = {32--39},
  doi = {10.1177/08968608241290019}
}
Kostenlos starten →