Susceptibility of hepato-splanchnic perfusion to intra-abdominal pressure in peritoneal dialysis patients
Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis · 2025
DOI: 10.1177/08968608241275922 ↗Kurz gefasst
Fachartikel in der Zeitschrift Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis, 2025. Verfasst von Werner Ribitsch und 4 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Division of Nephrology, Department of Internal Medicine, Medical University of Graz, Austria. Hauptthemen laut MEDLINE: Peritoneal Dialysis, Splanchnic Circulation, Kidney Failure, Chronic, Liver. Die Arbeit nennt 28 Literaturangaben.
Abstract (Originalsprache)
Background
The impact of peritoneal filling on hepato-splanchnic perfusion during peritoneal dialysis has not been fully elucidated yet.
Methods
Measurements were done in 20 prevalent peritoneal dialysis patients during a peritoneal equilibration test (PET) with 2L of standard dialysate. Data were obtained in the drained state at baseline ( T 0 ), after instillation ( T 1 ), and after 2 h of dwell time ( T 2 ). Intra-abdominal pressure (IAP) was measured by Durand's approach. The hepatic clearance index (KI) of indocyanine-green (ICG) was determined as an indirect measure of hepato-splanchnic blood flow. Cardiac index (CI), heart rate (HR), and total peripheral resistance index (TPRI) were derived from continuous arterial pulse analysis. Fluid volume overload (VO) was evaluated by multifrequency bioimpedance analysis. Ejection fraction (EF) was obtained from echocardiographic examination.
Results
IAP was 5.8 ± 3.5 mmHg at baseline ( T 0 ), rose to 9.4 ± 2.8 mmHg after instillation of dialysate ( T 1 ), and further to 9.7 ± 2.8 mmHg after 2 h of dwell time ( p < 0.001). KI slightly declined from 0.60 ± 0.22 L/min/m 2 at T 0 to 0.53 ± 0.15 L/min/m 2 at T 1 ( p = 0.075), and returned to 0.59 ± 0.22 L/min/m 2 at T 2 ( p = 0.052). CI, HR, and TPRI did not change significantly. In five patients with an EF < 40% KI was significantly lower at T 1 (0.42 ± 0.12 L/min/m 2 ; p = 0.039), and further decreased at T 2 (0.40 ± 0.04 L/min/m 2 ; p = 0.016) compared to patients with normal EF ( T 1 : 0.58 ± 0.15 L/min/m 2 and T 2 : 0.67 ± 0.22 L/min/m 2 ).
Conclusions
Overall, hepatic clearance of ICG as a marker of hepato-splanchnic blood flow is not affected by the filling of the peritoneal cavity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Clinical Division of Nephrology, Department of Internal Medicine, Medical University of Graz, Austria.
- Division of Physiology and Pathophysiology, Otto Loewi Research Center for Vascular Biology, Immunology and Inflammation, Medical University of Graz, Austria.
ORCID-Profile: Werner Ribitsch, Daniel Schneditz
Zitieren
APA
Ribitsch, W., Lehner, T. A., Sauseng, N., Rosenkranz, A. R., & Schneditz, D. (2025). Susceptibility of hepato-splanchnic perfusion to intra-abdominal pressure in peritoneal dialysis patients. Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis. https://doi.org/10.1177/08968608241275922
Vancouver
Ribitsch W, Lehner TA, Sauseng N, Rosenkranz AR, Schneditz D. Susceptibility of hepato-splanchnic perfusion to intra-abdominal pressure in peritoneal dialysis patients. Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis. 2025. doi:10.1177/08968608241275922
BibTeX
@article{Ribitsch2025,
author = {Ribitsch, Werner and Lehner, Thomas A and Sauseng, Notburga and Rosenkranz, Alexander R and Schneditz, Daniel},
title = {Susceptibility of hepato-splanchnic perfusion to intra-abdominal pressure in peritoneal dialysis patients},
journal = {Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis},
year = {2025},
doi = {10.1177/08968608241275922}
}
EUVIMED