Determining the residual volume in peritoneal dialysis using low molecular weight markers
Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis · 2025
DOI: 10.1177/08968608241260024 ↗Kurz gefasst
Fachartikel in der Zeitschrift Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis, 2025. Verfasst von Elin Lindholm und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Sciences Lund, Skane University Hospital, Lund University, Lund, Sweden. Hauptthemen laut MEDLINE: Peritoneal Dialysis, Urea, Creatinine, Dialysis Solutions. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Lund University Medical Faculty Foundation.
Abstract (Originalsprache)
Background
Variation in residual volume between peritoneal dialysis dwells creates uncertainty in ultrafiltration determination, dialysis efficiency, and poses a risk of overfill if the residual volume is large. Measuring the dilution of a marker molecule during fluid fill offers a convenient approach, however, estimation accuracy depends on the choice of dilution marker. We here evaluate the feasibility of creatinine and urea as dilution markers compared to albumin-based residual volumes and three-pore model estimations.
Method
This clinical, retrospective analysis comprises 56 residual volume estimations from 20 individuals, based on the dilution of pre-fill dialysate creatinine, urea and albumin concentrations during the dialysis fluid fill phase. Outcomes were compared individually. Bias induced by ultrafiltration, marker molecule mass-transfer and influence of fluid glucose contents was quantified using the three-pore model. Linear regression established conversion factors enabling conversion between the various marker molecules.
Results
Creatinine-based calculations overestimated residual volumes by 115 mL (IQR 89–149) in 1.5% dwells and 252 mL (IQR 179–313) in 4.25% glucose dwells. In hypertonic dwells, ultrafiltration was 52 mL (IQR 38–66), while intraperitoneal creatinine mass increased by 67% during fluid fill, being the leading cause of overestimation. Albumin-based volumes conformed strongly with three-pore model estimates. Correction factors effectively enabled marker molecule interchangeability.
Conclusions
Mass-transfer of low molecular weight marker molecules is associated with residual volume overestimation. However, by applying correction factors, creatinine and urea dilution can still provide reasonable estimates, particularly when the purpose is to exclude the presence of a very large residual volume.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Clinical Sciences Lund, Skane University Hospital, Lund University, Lund, Sweden.
ORCID-Profile: Carl M Öberg, Karin Bergling
Förderung
- Lund University Medical Faculty Foundation
Zitieren
APA
Lindholm, E., Martus, G., Öberg, C. M., & Bergling, K. (2025). Determining the residual volume in peritoneal dialysis using low molecular weight markers. Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis. https://doi.org/10.1177/08968608241260024
Vancouver
Lindholm E, Martus G, Öberg CM, Bergling K. Determining the residual volume in peritoneal dialysis using low molecular weight markers. Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis. 2025. doi:10.1177/08968608241260024
BibTeX
@article{Lindholm2025,
author = {Lindholm, Elin and Martus, Giedre and Öberg, Carl M and Bergling, Karin},
title = {Determining the residual volume in peritoneal dialysis using low molecular weight markers},
journal = {Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis},
year = {2025},
doi = {10.1177/08968608241260024}
}
EUVIMED