EUVIMEDEUVIMED entdecken
Crossref

Evaluation of wedge-induced photoneutron dose during 15 MV 3D conformal rectal radiotherapy using TLD600/TLD700 pairs

Tahir Çakır iD, Hikmettin Demir iD, Osman Vefa Gül iD, Nurhak Tatar iD, Rafet Yılmaz iD

Journal of X-Ray Science and Technology · 18.11.2026

DOI: 10.1177/08953996261509409 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology, online erschienen am 18.11.2026. Verfasst von Tahir Çakır und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biophysics, Van Yuzuncu Yil University, Van, Türkiye. Die Arbeit nennt 39 Literaturangaben. Gefördert von: Bilimsel Araştırma Projeleri Koordinasyon Birimi, Yüzüncü Yil Üniversitesi.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Linear accelerators are widely used in radiotherapy. However, photoneutron production may occur during high energy photon radiotherapy. Neutrons have a high radiation weighting factor.

Purpose

To compare the thermal neutron sensitive TLD responses with and without wedge use during simulated rectal radiotherapy using TLD600/700 pairs.

Methods

TLD pairs were placed in the target (rectal region), bladder, and right femur regions of an anthropomorphic Rando phantom for simulated rectal radiotherapy. Computed tomography images were acquired and transferred to the Prowess treatment planning system (TPS). Wedge and non-wedge plans were created using 15 MV photons at a treatment dose of 2 Gy. Plans were delivered using a Siemens Artiste™ linear accelerator. TLDs were read using a Harshaw system, and Am–Be calibrated neutron sensitive responses were expressed in mSv/Gy. Wedge/non-wedge response ratios were also calculated.

Results

Am–Be calibrated values for wedge versus non-wedge plans were 0.37 vs. 0.19 mSv/Gy for the target, 0.43 vs. 0.17 mSv/Gy for the bladder, and 0.51 vs. 0.22 mSv/Gy for the right femur, corresponding to wedge/non-wedge ratios of 1.95, 2.53, and 2.32, respectively.

Conclusions

Neutron sensitive TLD responses were higher for the wedge plan than for the non-wedge plan at the same measurement positions.

Schlagwörter

Stichwörter der Autor:innen

TLD600/700 pairsdosimetrylinear acceleratorphotoneutronrectal cancerwedge

Autor:innen und Institutionen

  • Department of Biophysics, Van Yuzuncu Yil University, Van, Türkiye.
  • Department of Radiation Oncology, Van Yuzuncu Yil University, Van, Türkiye.
  • Department of Radiation Oncology, Selçuk University, Konya, Türkiye.
  • Department of Nuclear Engineering, Hacettepe University, Ankara, Türkiye.
  • Department of Physics, Van Yuzuncu Yil University, Van, Türkiye.

ORCID-Profile: Tahir Çakır, Hikmettin Demir, Osman Vefa Gül, Nurhak Tatar, Rafet Yılmaz

Förderung

  • Bilimsel Araştırma Projeleri Koordinasyon Birimi, Yüzüncü Yil Üniversitesi

Zitieren

APA

Çakır, T., Demir, H., Gül, O. V., Tatar, N., & Yılmaz, R. (2026). Evaluation of wedge-induced photoneutron dose during 15 MV 3D conformal rectal radiotherapy using TLD600/TLD700 pairs. Journal of X-Ray Science and Technology. https://doi.org/10.1177/08953996261509409

Vancouver

Çakır T, Demir H, Gül OV, Tatar N, Yılmaz R. Evaluation of wedge-induced photoneutron dose during 15 MV 3D conformal rectal radiotherapy using TLD600/TLD700 pairs. Journal of X-Ray Science and Technology. 2026. doi:10.1177/08953996261509409

BibTeX
@article{akr2026,
  author = {Çakır, Tahir and Demir, Hikmettin and Gül, Osman Vefa and Tatar, Nurhak and Yılmaz, Rafet},
  title = {Evaluation of wedge-induced photoneutron dose during 15 MV 3D conformal rectal radiotherapy using TLD600/TLD700 pairs},
  journal = {Journal of X-Ray Science and Technology},
  year = {2026},
  doi = {10.1177/08953996261509409}
}
Kostenlos starten →