Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology, online erschienen am 17.08.2026. Verfasst von S I Mahizha und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Information Technology, St Xavier's Catholic College of Engineering, Nagercoil, India. Hauptthemen laut MEDLINE: Radiography, Panoramic, Radiographic Image Interpretation, Computer-Assisted. Die Arbeit nennt 39 Literaturangaben.
Abstract (Originalsprache)
Background
Automatic detection and segmentation of dental diseases from panoramic x-ray images have been a difficult task to achieve due to the problems of class imbalance and varying sizes of lesions, as well as the inconspicuous nature of early caries. This paper introduces SwinDent-Seg, which is a hybrid architecture of Swin Transformer-CNN that includes CSFF module, ECMA attention, and high-resolution P 2 detection head.
Methods
The proposed model was trained and evaluated on a dataset of 1018 annotated panoramic radiographs comprising seven dental pathology classes. Model development and hyperparameter optimization were performed using a validation set (220 images). SwinDent-Seg was compared with multiple CNN- and Transformer-based baselines, including YOLOv8, YOLO11 and RT-DETR-L. A confidence-weighted ensemble combining SwinDent-Seg and YOLOv8m-seg was subsequently evaluated on an independent test set (81 images).
Results
On the validation set, SwinDent-Seg achieved the best single-model performance, with an mAP50 of 0.8947, outperforming all baseline models, including YOLOv8m-seg (mAP50 = 0.6770). The proposed architecture markedly improved caries detection, increasing AP50 from 0.134 to 0.8953. On the independent test set, the confidence-weighted ensemble (SwinDent-Seg + YOLOv8m-seg) achieved the best overall performance, with an mAP50 of 0.9289 and a macro-AUC of 0.9515, exceeding the performance of either individual model.
Conclusion
SwinDent-Seg demonstrates superior single-model validation performance, while the confidence-weighted ensemble provides the highest independent test-set performance. These findings indicate that combining Transformer-based global contextual representation with CNN-based localization improves robust multi-class dental pathology segmentation and supports the development of reliable computer-aided diagnostic systems for panoramic radiographs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Information Technology, St Xavier's Catholic College of Engineering, Nagercoil, India.
- Department of Conservative Dentistry and Endodontics, Sree Mookambika Institute of Dental Sciences, Kulasekaram, India.
ORCID-Profile: S I Mahizha, J Annrose, J Mano Christaine Angelo
Zitieren
APA
Mahizha, S. I., Annrose, J., & Mano Christaine Angelo, J. (2026). SwinDent-Seg: Hybrid Swin transformer-CNN with cross-scale feature fusion for automated detection and segmentation of dental pathologies in panoramic radiographs. Journal of X-Ray Science and Technology, 34(6), 723-739. https://doi.org/10.1177/08953996261478470
Vancouver
Mahizha SI, Annrose J, Mano Christaine Angelo J. SwinDent-Seg: Hybrid Swin transformer-CNN with cross-scale feature fusion for automated detection and segmentation of dental pathologies in panoramic radiographs. Journal of X-Ray Science and Technology. 2026;34(6):723-739. doi:10.1177/08953996261478470
BibTeX
@article{Mahizha2026,
author = {Mahizha, S I and Annrose, J and Mano Christaine Angelo, J},
title = {SwinDent-Seg: Hybrid Swin transformer-CNN with cross-scale feature fusion for automated detection and segmentation of dental pathologies in panoramic radiographs},
journal = {Journal of X-Ray Science and Technology},
year = {2026},
volume = {34},
number = {6},
pages = {723--739},
doi = {10.1177/08953996261478470}
}
EUVIMED