Vergleichsstudie in der Zeitschrift Journal of X-Ray Science and Technology, online erschienen am 23.04.2026. Verfasst von Elif Yeşil und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Evliya Çelebi Training and Research Hospital, Kütahya Health Sciences University, Kütahya, Türkiye. Hauptthemen laut MEDLINE: Brain Neoplasms, Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated. Die Arbeit nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To compare treatment plans created using the Eclipse and Prowess treatment planning systems for patients diagnosed with high-grade brain tumors in the left temporal lobe and to evaluate target volume coverage and doses delivered to critical organs using intensity-modulated radiotherapy (IMRT) technique. Materials and Methods: This retrospective comparative planning study included 15 patients. Plans were created on CT images using step-and-shoot IMRT with 6 MV photons. Eclipse used the Pencil Beam Convolution (PBC) algorithm, while Prowess used the Collapsed Cone Convolution (CCCS) algorithm. A total dose of 60 Gy in 30 fractions was prescribed. Dosimetric parameters were analyzed statistically.

Results

Both TPSs achieved comparable target coverage, with no significant differences in conformity and homogeneity indices (p = 0.075 and p = 0.590, respectively) or dose–volume parameters (D95, D98, D2; p > 0.05). Eclipse provided significantly lower doses to the ipsilateral lens, brainstem, left optic nerve, cochlea, and whole brain V40 (p < 0.05).

Conclusion

Both TPSs demonstrated adequate target coverage; however, Eclipse achieved statistically significant dose reductions in several critical structures, which may have clinical relevance in reducing toxicity risk.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Brain NeoplasmsRadiotherapy Planning, Computer-AssistedRadiotherapy, Intensity-ModulatedHumansRetrospective StudiesRadiotherapy DosageFemaleAlgorithmsTomography, X-Ray ComputedMaleOrgans at RiskMiddle AgedAdult

Stichwörter der Autor:innen

high-grade brain tumorintensity-modulated radiotherapytreatment planning system

Autor:innen und Institutionen

  • Department of Radiation Oncology, Evliya Çelebi Training and Research Hospital, Kütahya Health Sciences University, Kütahya, Türkiye.
  • Department of Radiation Oncology, Faculty of Medicine, Necmettin Erbakan University, Konya, Türkiye.
  • Department of Radiation Oncology, Faculty of Medicine, Van Yuzuncu Yıl University, Van, Türkiye.

Zitieren

APA

Yeşil, E., Aktan, M., Şahin, A., & Demir, H. (2026). Comparison of treatment plans for patients with high-grade brain tumors using two different treatment planning systems in radiotherapy. Journal of X-Ray Science and Technology, 34(4), 479-488. https://doi.org/10.1177/08953996261444398

Vancouver

Yeşil E, Aktan M, Şahin A, Demir H. Comparison of treatment plans for patients with high-grade brain tumors using two different treatment planning systems in radiotherapy. Journal of X-Ray Science and Technology. 2026;34(4):479-488. doi:10.1177/08953996261444398

BibTeX
@article{Yeil2026,
  author = {Yeşil, Elif and Aktan, Meryem and Şahin, Ahmet and Demir, Hikmettin},
  title = {Comparison of treatment plans for patients with high-grade brain tumors using two different treatment planning systems in radiotherapy},
  journal = {Journal of X-Ray Science and Technology},
  year = {2026},
  volume = {34},
  number = {4},
  pages = {479--488},
  doi = {10.1177/08953996261444398}
}
Kostenlos starten →