Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology, 2025. Verfasst von Shuming Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Computer Science and Technology (College of Data Science), Taiyuan University of Technology, Taiyuan, China. Hauptthemen laut MEDLINE: Pneumoconiosis, Radiography, Thoracic, Radiographic Image Interpretation, Computer-Assisted. Die Arbeit nennt 43 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Funding Project of Local Science and Technology Development Guided by Central Government of China, Open Project of National Health Commission Key Laboratory of Pneumoconiosis, China.
Abstract (Originalsprache)
Background
The precise pneumoconiosis staging suffers from progressive pair label noise (PPLN) in chest X-ray datasets, because adjacent stages are confused due to unidentifialble and diffuse opacities in the lung fields. As deep neural networks are employed to aid the disease staging, the performance is degraded under such label noise.
Objective
This study improves the effectiveness of pneumoconiosis staging by mitigating the impact of PPLN through network architecture refinement and sample selection mechanism adjustment.
Methods
We propose a novel multi-branch architecture that incorporates the dual-threshold sample selection. Several auxiliary branches are integrated in a two-phase module to learn and predict the progressive feature tendency . A novel difference-based metric is introduced to iteratively obtained the instance-specific thresholds as a complementary criterion of dynamic sample selection. All the samples are finally partitioned into clean and hard sets according to dual-threshold criteria and treated differently by loss functions with penalty terms.
Results
Compared with the state-of-the-art, the proposed method obtains the best metrics (accuracy: 90.92%, precision: 84.25%, sensitivity: 81.11%, F1-score: 82.06%, and AUC: 94.64%) under real-world PPLN, and is less sensitive to the rise of synthetic PPLN rate. An ablation study validates the respective contributions of critical modules and demonstrates how variations of essential hyperparameters affect model performance.
Conclusions
The proposed method achieves substantial effectiveness and robustness against PPLN in pneumoconiosis dataset, and can further assist physicians in diagnosing the disease with a higher accuracy and confidence.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Computer Science and Technology (College of Data Science), Taiyuan University of Technology, Taiyuan, China.
- School of Software, North University of China, Taiyuan, China.
- School of Software, Taiyuan University of Technology, Taiyuan, China.
- College of Information, Jinzhong College of Information, Jinzhong, China.
- First Hospital of Shanxi Medical University, Taiyuan, China.
Förderung
- National Natural Science Foundation of China
- Funding Project of Local Science and Technology Development Guided by Central Government of China
- Open Project of National Health Commission Key Laboratory of Pneumoconiosis, China
- Special Fund for Science and Technology Innovation Teams of Shanxi Province, China
- Non-profit Central Research Institute Fund of Chinese Academy of Medical Science
Zitieren
APA
Zhang, S., Ren, X., Qiang, Y., Zhao, J., Qiao, Y., & Yue, H. (2025). Dual-threshold sample selection with latent tendency difference for label-noise-robust pneumoconiosis staging. Journal of X-Ray Science and Technology. https://doi.org/10.1177/08953996251319652
Vancouver
Zhang S, Ren X, Qiang Y, Zhao J, Qiao Y, Yue H. Dual-threshold sample selection with latent tendency difference for label-noise-robust pneumoconiosis staging. Journal of X-Ray Science and Technology. 2025. doi:10.1177/08953996251319652
BibTeX
@article{Zhang2025,
author = {Zhang, Shuming and Ren, Xueting and Qiang, Yan and Zhao, Juanjuan and Qiao, Ying and Yue, Huajie},
title = {Dual-threshold sample selection with latent tendency difference for label-noise-robust pneumoconiosis staging},
journal = {Journal of X-Ray Science and Technology},
year = {2025},
doi = {10.1177/08953996251319652}
}
EUVIMED