Deep Learning Analysis of Indocyanine Green Fluoroscopy of Ureters in Robotic Cystectomy: Toward Reducing Ureteroenteric Strictures
Journal of Endourology · 01.08.2026 · 40 (8) · 935-940
DOI: 10.1177/08927790261450709 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Endourology, online erschienen am 20.05.2026. Verfasst von Aron F H A Bakker und 10 weiteren Autor:innen. Beteiligte Einrichtung: University Medical Center Utrecht, Utrecht, Netherlands. Hauptthemen laut MEDLINE: Indocyanine Green, Ureter, Robotic Surgical Procedures, Deep Learning. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 10 Literaturangaben.
Abstract (Originalsprache)
Objectives
To develop a deep learning method to quantify ureter perfusion during indocyanine green (ICG) fluoroscopy in robot-assisted radical cystectomy (RARC).
Introduction
Ureteroenteric stricture (UES) is a common and clinically significant complication of RARC. Ureter ICG fluoroscopy likely reduces UES rates. However, its current reliance on subjective visual interpretation warrants a quantitative assessment method. Materials and Methods: A single-center retrospective pilot study was performed using 96 videos of RARC with ICG fluoroscopy, recorded between November 2019 and June 2024. Afterwards, 251 full-color and 358 ICG frames of suspended ureters were randomly split into 80/20% training and test sets and were annotated. A surgical foundation model, SurgeNetXL, which was readily pre-trained, was trained on the training sets. Performance was assessed using the Dice Similarity Coefficient (DSC) and Hausdorff Distance (HD). Each ureter segmentation was divided into 50 horizontal planes with green intensity sampling points to calculate five perfusion parameters, including time to peak and normalized peak slope. These parameters were combined into a single composite “perfusion score” per plane. A stable and manually annotated video was used for a proof of concept.
Results
The model performed well in segmenting full-color ureters (DSC = 0.800, HD = 24 pixels). Regarding ureters in ICG fluoroscopy, the model also performed well (DSC = 0.767, HD = 61 pixels), despite worse visibility. There was a good subjective visual correspondence between the perfusion score graphical overlay and the green intensity in the video.
Conclusions
This pre-clinical study shows promising steps toward automated assistance of ureter dissection plane determination during RARC, aimed at reducing UES in a data-driven manner. Additional steps are required to improve the technique and to enable fully automated intensity measurements, which are needed to study correlations with UES outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- University Medical Center Utrecht, Utrecht, Netherlands.
- Catharina Ziekenhuis Eindhoven, Eindhoven, Netherlands.
- Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands.
- University of Twente, Enschede, Netherlands.
ORCID-Profile: Aron F H A Bakker
Zitieren
APA
Bakker, A. F. H. A., Jaspers, T. J. M., Baan, J. G. J. J., Duyvesteyn, M. J., van der Duin, J., Hillebrink, S. F., Meijer, R. P., Willemse, P. M., Ruurda, J. P., van der Sommen, F., & Brinkman, W. M. (2026). Deep Learning Analysis of Indocyanine Green Fluoroscopy of Ureters in Robotic Cystectomy: Toward Reducing Ureteroenteric Strictures. Journal of Endourology, 40(8), 935-940. https://doi.org/10.1177/08927790261450709
Vancouver
Bakker AFHA, Jaspers TJM, Baan JGJJ, Duyvesteyn MJ, van der Duin J, Hillebrink SF, et al. Deep Learning Analysis of Indocyanine Green Fluoroscopy of Ureters in Robotic Cystectomy: Toward Reducing Ureteroenteric Strictures. Journal of Endourology. 2026;40(8):935-940. doi:10.1177/08927790261450709
BibTeX
@article{Bakker2026,
author = {Bakker, Aron F H A and Jaspers, Tim J M and Baan, Jesse G J J and Duyvesteyn, Maarten J and van der Duin, Jesse and Hillebrink, Sanne F and Meijer, Richard P and Willemse, Peter-Paul M and Ruurda, Jelle P and van der Sommen, Fons and Brinkman, Willem M},
title = {Deep Learning Analysis of Indocyanine Green Fluoroscopy of Ureters in Robotic Cystectomy: Toward Reducing Ureteroenteric Strictures},
journal = {Journal of Endourology},
year = {2026},
volume = {40},
number = {8},
pages = {935--940},
doi = {10.1177/08927790261450709}
}
EUVIMED