EUVIMEDEUVIMED entdecken
Crossref

Biocompatibility and antibacterial activity of strontium and silver ion-releasing titanium with high silver treatment concentration

Kazuki Orita iD, Shunsuke Fujibayashi, Yaichiro Okuzu, Seiji Yamaguchi, Koji Goto, Bungo Otsuki, Toshiyuki Kawai, Takayoshi Shimizu, Makoto Hayashi, Norimasa Ikeda, Yusuke Takaoka, Shintaro Honda und 2 weitere

Journal of Biomaterials Applications · 2025

DOI: 10.1177/08853282251329276 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biomaterials Applications, 2025. Verfasst von Kazuki Orita und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Kyoto University Graduate School of Medicine, Kyoto, Japan. Hauptthemen laut MEDLINE: Strontium, Silver, Titanium, Anti-Bacterial Agents. Die Arbeit nennt 53 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To overcome problems associated with surgical site infection and implant loosening, we developed a titanium (Ti)-based material employing a modified alkaline heat treatment that releases strontium (Sr) and silver (Ag) ions (CaSrAg-Ti). In this study, to determine the optimal Ag treatment concentration, we prepared four different materials—commercially pure Ti (cp-Ti) as a negative control, CaSr1mMAg-Ti, CaSr10mMAg-Ti, and CaSr50mMAg-Ti. Ion release test was performed by immersing the prepared disks in fetal bovine serum. With increased loading of Ag ions, the amount of released ions increased. Colony-forming unit count assay was performed using methicillin-susceptible Staphylococcus aureus and Escherichia coli . High antibacterial activity was observed in CaSr10mMAg-Ti and CaSr50mMAg-Ti groups. In vivo experiments were performed using the rat subcutaneous pocket infection model and evaluated by counting the attached bacteria, wound appearance, and histological evaluation. High antibacterial activity value (AAV >2) and anti-inflammatory effects were observed in the CaSr50mMAg-Ti group. However, CaSr10mMAg-Ti did not exhibit consistent antibacterial activity. For in vivo biocompatibility and bone-bonding ability evaluation, rods were implanted into the rat femur. No cytotoxicity was observed at 1 week, and good bone-bonding ability at 4 and 8 weeks was not significantly different from that of CaSr1mMAg-Ti. To evaluate in vivo bioactivity and cytotoxicity, MC3T3-E1 cells were cultured on disks. CaSr10mMAg-Ti and CaSr50mMAg-Ti significantly inhibited the proliferation and differentiation of MC3T3E1 cells, as well as the production of extracellular matrix in vivo , despite showing good biocompatibility in vivo . In conclusion, CaSr50mMAg-Ti, with increased Ag ion loading, exhibited high antibacterial activity in vivo while maintaining the bone-bonding ability and is a promising therapeutic biomaterial. Further research is needed to determine the optimal combination of therapeutic concentrations of Sr and Ag.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

StrontiumSilverTitaniumAnti-Bacterial AgentsBiocompatible MaterialsAnimalsRatsStaphylococcus aureusMiceEscherichia coliMaterials TestingRats, Sprague-DawleyMaleOsteoblasts

Stichwörter der Autor:innen

Alkaline heat treatmentanti-inflammatoryantibacterialbone-bondingsilverstrontiumtitanium

Substanzen

StrontiumSilverTitaniumAnti-Bacterial AgentsBiocompatible Materials

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Kyoto University Graduate School of Medicine, Kyoto, Japan.
  • Department of Biomedical Sciences, College of Life and Health Sciences, Chubu University, Kasugai, Japan.
  • Department of Orthopaedic Surgery, Kindai University Hospital, Osaka-Sayama, Japan.

ORCID-Profile: Kazuki Orita

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Orita, K., Fujibayashi, S., Okuzu, Y., Yamaguchi, S., Goto, K., Otsuki, B., Kawai, T., Shimizu, T., Hayashi, M., Ikeda, N., Takaoka, Y., Honda, S., Ikezaki, T., & Matsuda, S. (2025). Biocompatibility and antibacterial activity of strontium and silver ion-releasing titanium with high silver treatment concentration. Journal of Biomaterials Applications. https://doi.org/10.1177/08853282251329276

Vancouver

Orita K, Fujibayashi S, Okuzu Y, Yamaguchi S, Goto K, Otsuki B, et al. Biocompatibility and antibacterial activity of strontium and silver ion-releasing titanium with high silver treatment concentration. Journal of Biomaterials Applications. 2025. doi:10.1177/08853282251329276

BibTeX
@article{Orita2025,
  author = {Orita, Kazuki and Fujibayashi, Shunsuke and Okuzu, Yaichiro and Yamaguchi, Seiji and Goto, Koji and Otsuki, Bungo and Kawai, Toshiyuki and Shimizu, Takayoshi and Hayashi, Makoto and Ikeda, Norimasa and Takaoka, Yusuke and Honda, Shintaro and Ikezaki, Tatsuhito and Matsuda, Shuichi},
  title = {Biocompatibility and antibacterial activity of strontium and silver ion-releasing titanium with high silver treatment concentration},
  journal = {Journal of Biomaterials Applications},
  year = {2025},
  doi = {10.1177/08853282251329276}
}
Kostenlos starten →