EUVIMEDEUVIMED entdecken
Systematische Übersicht

Comparing the Accuracy of Mini-BAL to Bronchoscopic BAL in the Diagnosis of Pneumonia Among Ventilated Patients: A Systematic Literature Review

John Tepper iD, Sean Johnson, Connor Parker, James Collins, Laura Menard, Laura Hinkle

Journal of Intensive Care Medicine · 2023

DOI: 10.1177/08850666231193379 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Journal of Intensive Care Medicine, 2023. Verfasst von John Tepper und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, Indiana University School of Medicine, Indianapolis, IN, USA. Hauptthemen laut MEDLINE: Respiration, Artificial, Pneumonia. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Despite its widespread use, there are no direct studies comparing mini-bronchoalveolar lavage (mini-BAL) to bronchoscopic bronchoalveolar lavage (BAL) for diagnosing pneumonia in ventilated patients. The aim of this study was to perform a systematic review of studies comparing ventilated patients undergoing both bronchoscopic BAL and mini-BAL, to determine the mini-BAL's diagnostic accuracy.

Methods

We conducted a systematic review searching the databases PubMed (MEDLINE), EMBASE, Cochrane Library, Scopus, and clinicaltrials.gov from inception until January 2022, in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Search terms included variations on “pneumonia,” “critical illness,” and “mini-bronchoalveolar lavage.” Article screening and data extraction were performed independently by 2 reviewers.

Results

Our search yielded 4296 abstracts. This was narrowed to 6 studies in which each patient underwent both mini-BAL and bronchoscopic BAL in succession. Included patients had a mean APACHE II score of 20.02 ± 3.81 and 15.95 ± 11.46 ventilator days. The sensitivity of the mini-BAL for diagnosis of pneumonia was 0.90 (95% confidence interval [CI]: 0.778-1.000) and the specificity was 0.827 (95% CI: 0.716-0.938). Limitations included inconsistency in volume of saline instilled and heterogeneity in included patients Conclusion: This study is the first to compile data from multiple publications directly comparing the mini-BAL to bronchoscopic BAL for diagnosing pneumonia in ventilated patients. Our data demonstrate a high degree of both sensitivity and specificity of mini-BAL for the diagnosis of pneumonia in ventilated patients and indicate that mini-BAL could be considered as an acceptable alternative diagnostic study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Respiration, ArtificialPneumoniaHumansBronchoalveolar Lavage FluidProspective StudiesBronchoalveolar Lavage

Stichwörter der Autor:innen

critical caremechanical ventilationpneumonia

Autor:innen und Institutionen

  • Department of Internal Medicine, Indiana University School of Medicine, Indianapolis, IN, USA.
  • Department of Pediatrics, Indiana University School of Medicine, Indianapolis, IN, USA.
  • Libary and Information Science, Northern Kentucky University, Highland Heights, KY, USA.
  • Division of Pulmonary, Critical Care, Sleep & Occupational Medicine, Indiana University School of Medicine, Indianapolis, IN, USA.

ORCID-Profile: John Tepper

Zitieren

APA

Tepper, J., Johnson, S., Parker, C., Collins, J., Menard, L., & Hinkle, L. (2023). Comparing the Accuracy of Mini-BAL to Bronchoscopic BAL in the Diagnosis of Pneumonia Among Ventilated Patients: A Systematic Literature Review. Journal of Intensive Care Medicine. https://doi.org/10.1177/08850666231193379

Vancouver

Tepper J, Johnson S, Parker C, Collins J, Menard L, Hinkle L. Comparing the Accuracy of Mini-BAL to Bronchoscopic BAL in the Diagnosis of Pneumonia Among Ventilated Patients: A Systematic Literature Review. Journal of Intensive Care Medicine. 2023. doi:10.1177/08850666231193379

BibTeX
@article{Tepper2023,
  author = {Tepper, John and Johnson, Sean and Parker, Connor and Collins, James and Menard, Laura and Hinkle, Laura},
  title = {Comparing the Accuracy of Mini-BAL to Bronchoscopic BAL in the Diagnosis of Pneumonia Among Ventilated Patients: A Systematic Literature Review},
  journal = {Journal of Intensive Care Medicine},
  year = {2023},
  doi = {10.1177/08850666231193379}
}
Kostenlos starten →