Discrepancies in Vessel Diameter Measurements Between CTA and DSA in MCA M1 Occlusions: An Interobserver Study
Canadian Association of Radiologists Journal · 2026
DOI: 10.1177/08465371251356908 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Canadian Association of Radiologists Journal, 2026. Verfasst von Patrick Rogers und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Imaging, Dalhousie University, Halifax, NS, Canada. Hauptthemen laut MEDLINE: Angiography, Digital Subtraction, Computed Tomography Angiography, Infarction, Middle Cerebral Artery, Cerebral Angiography. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Accurate vessel measurement is essential in endovascular thrombectomy (EVT) for acute ischemic stroke. Discrepancies between computed tomography angiography (CTA) and digital subtraction angiography (DSA) may impact procedural planning and device selection. This study compares vessel diameter measurements from CTA and DSA in patients with middle cerebral artery (MCA) M1 occlusions.
Methods
In this single-center retrospective study, 90 consecutive patients who underwent EVT for MCA M1 occlusions between February 2020 and March 2024 were included. Vessel diameters were independently measured by 3 neuroradiologists using CTA and DSA (pre- and post-intervention). Statistical analysis included Wilcoxon signed-rank tests, intraclass correlation coefficient (ICC), and Bland–Altman analysis.
Results
CTA consistently overestimated vessel diameter compared to DSA. The mean M1 diameter was 2.29 ± 0.27 mm on CTA and 2.16 ± 0.30 mm on pre-EVT DSA ( P < .001), with a median difference of 0.4 mm (IQR: 0.2-0.6 mm). In 70% of cases, CTA values exceeded DSA. Bland–Altman analysis confirmed a mean difference of +0.13 mm (limits of agreement: −0.25 to +0.51 mm). No significant change was observed between pre- and post-EVT DSA measurements ( P = .103). Clot-side M1 segments were significantly smaller than contralateral measurements on CTA ( P = .003). Inter-rater agreement was good (ICC = .785).
Conclusions
CTA overestimates MCA M1 diameter relative to DSA. While the discrepancy is modest, it may influence device selection in borderline cases. Awareness of this variability is important, and further research is warranted to explore its clinical implications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Diagnostic Imaging, Dalhousie University, Halifax, NS, Canada.
- Department of Surgery, Division of Neurosurgery, Dalhousie University, Halifax, NS, Canada.
- Department of Diagnostic Imaging, Division of Neuroradiology, University of Toronto, Toronto Western Hospital, University Health Network, Toronto, ON, Canada.
ORCID-Profile: Patrick Rogers, Ian R MacDonald, Cha-Ney Kim, Eef J Hendriks
Zitieren
APA
Rogers, P., Parker, E., Marangoni, M., MacDonald, I. R., Kim, C. N., Hendriks, E. J., & Volders, D. (2026). Discrepancies in Vessel Diameter Measurements Between CTA and DSA in MCA M1 Occlusions: An Interobserver Study. Canadian Association of Radiologists Journal. https://doi.org/10.1177/08465371251356908
Vancouver
Rogers P, Parker E, Marangoni M, MacDonald IR, Kim CN, Hendriks EJ, et al. Discrepancies in Vessel Diameter Measurements Between CTA and DSA in MCA M1 Occlusions: An Interobserver Study. Canadian Association of Radiologists Journal. 2026. doi:10.1177/08465371251356908
BibTeX
@article{Rogers2026,
author = {Rogers, Patrick and Parker, Ellen and Marangoni, Marco and MacDonald, Ian R and Kim, Cha-Ney and Hendriks, Eef J and Volders, David},
title = {Discrepancies in Vessel Diameter Measurements Between CTA and DSA in MCA M1 Occlusions: An Interobserver Study},
journal = {Canadian Association of Radiologists Journal},
year = {2026},
doi = {10.1177/08465371251356908}
}
EUVIMED