EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Discrepancies in Vessel Diameter Measurements Between CTA and DSA in MCA M1 Occlusions: An Interobserver Study

Patrick Rogers iD, Ellen Parker, Marco Marangoni, Ian R MacDonald iD, Cha-Ney Kim iD, Eef J Hendriks iD, David Volders

Canadian Association of Radiologists Journal · 2026

DOI: 10.1177/08465371251356908 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Canadian Association of Radiologists Journal, 2026. Verfasst von Patrick Rogers und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Imaging, Dalhousie University, Halifax, NS, Canada. Hauptthemen laut MEDLINE: Angiography, Digital Subtraction, Computed Tomography Angiography, Infarction, Middle Cerebral Artery, Cerebral Angiography. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Accurate vessel measurement is essential in endovascular thrombectomy (EVT) for acute ischemic stroke. Discrepancies between computed tomography angiography (CTA) and digital subtraction angiography (DSA) may impact procedural planning and device selection. This study compares vessel diameter measurements from CTA and DSA in patients with middle cerebral artery (MCA) M1 occlusions.

Methods

In this single-center retrospective study, 90 consecutive patients who underwent EVT for MCA M1 occlusions between February 2020 and March 2024 were included. Vessel diameters were independently measured by 3 neuroradiologists using CTA and DSA (pre- and post-intervention). Statistical analysis included Wilcoxon signed-rank tests, intraclass correlation coefficient (ICC), and Bland–Altman analysis.

Results

CTA consistently overestimated vessel diameter compared to DSA. The mean M1 diameter was 2.29 ± 0.27 mm on CTA and 2.16 ± 0.30 mm on pre-EVT DSA ( P < .001), with a median difference of 0.4 mm (IQR: 0.2-0.6 mm). In 70% of cases, CTA values exceeded DSA. Bland–Altman analysis confirmed a mean difference of +0.13 mm (limits of agreement: −0.25 to +0.51 mm). No significant change was observed between pre- and post-EVT DSA measurements ( P = .103). Clot-side M1 segments were significantly smaller than contralateral measurements on CTA ( P = .003). Inter-rater agreement was good (ICC = .785).

Conclusions

CTA overestimates MCA M1 diameter relative to DSA. While the discrepancy is modest, it may influence device selection in borderline cases. Awareness of this variability is important, and further research is warranted to explore its clinical implications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Angiography, Digital SubtractionComputed Tomography AngiographyInfarction, Middle Cerebral ArteryCerebral AngiographyMiddle Cerebral ArteryHumansRetrospective StudiesMaleFemaleAgedMiddle AgedObserver VariationThrombectomyAged, 80 and overReproducibility of ResultsEndovascular Procedures

Stichwörter der Autor:innen

computed tomography angiographydigital subtraction angiographyendovascular thrombectomymiddle cerebral arterystroke

Autor:innen und Institutionen

  • Department of Diagnostic Imaging, Dalhousie University, Halifax, NS, Canada.
  • Department of Surgery, Division of Neurosurgery, Dalhousie University, Halifax, NS, Canada.
  • Department of Diagnostic Imaging, Division of Neuroradiology, University of Toronto, Toronto Western Hospital, University Health Network, Toronto, ON, Canada.

ORCID-Profile: Patrick Rogers, Ian R MacDonald, Cha-Ney Kim, Eef J Hendriks

Zitieren

APA

Rogers, P., Parker, E., Marangoni, M., MacDonald, I. R., Kim, C. N., Hendriks, E. J., & Volders, D. (2026). Discrepancies in Vessel Diameter Measurements Between CTA and DSA in MCA M1 Occlusions: An Interobserver Study. Canadian Association of Radiologists Journal. https://doi.org/10.1177/08465371251356908

Vancouver

Rogers P, Parker E, Marangoni M, MacDonald IR, Kim CN, Hendriks EJ, et al. Discrepancies in Vessel Diameter Measurements Between CTA and DSA in MCA M1 Occlusions: An Interobserver Study. Canadian Association of Radiologists Journal. 2026. doi:10.1177/08465371251356908

BibTeX
@article{Rogers2026,
  author = {Rogers, Patrick and Parker, Ellen and Marangoni, Marco and MacDonald, Ian R and Kim, Cha-Ney and Hendriks, Eef J and Volders, David},
  title = {Discrepancies in Vessel Diameter Measurements Between CTA and DSA in MCA M1 Occlusions: An Interobserver Study},
  journal = {Canadian Association of Radiologists Journal},
  year = {2026},
  doi = {10.1177/08465371251356908}
}
Kostenlos starten →