Polyetheretherketone Polymer Transpedicular Vertebral System to Treat Vertebral Compression Fracture: A Multicentre Pilot Study of Feasibility and Safety
Canadian Association of Radiologists Journal · 2024
DOI: 10.1177/08465371241228256 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Canadian Association of Radiologists Journal, 2024. Verfasst von Matthias Barral und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Interventional Radiology, Tenon Hospital, APHP, Sorbonne Université, Paris, France. Hauptthemen laut MEDLINE: Fractures, Compression, Benzophenones, Polymers, Ketones. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, NIH/NCI Cancer Center.
Abstract (Originalsprache)
Objectives
To prospectively evaluate the feasibility and safety of a polyetheretherketone (PEEK) polymer transpedicular vertebral system to treat vertebral compression fracture (VCF).
Methods
Nine consecutive patients (4 men and 5 women; median age 59 [interquartile range: 58-64 years]) were included. The procedure duration, length of hospital stay, and complications were reported. Visual analog scale (VAS) and the Oswestry disability index (ODI) for pain and disability were assessed before and at 2, 6, and 12-month after the procedure.
Results
The procedure was technically feasible in all patients. The median procedural time was 64 minutes [45-94]. Only minor adverse events were reported (5 clinically asymptomatic cement leakages) but no severe complications. No post procedural adjacent fracture was reported during follow-up (median: 193 days [147-279]). The median VAS score decreased from 55 mm [50-70] before the procedure to 25 mm [5-30] at 2-month ( P = .0003) and 30 mm [15-40] at 6-month follow-up ( P = .14). The median ODI decreased from 23% [19-26] before the procedure to 12% [10-14] at 2-month ( P = .03) and 12% [9-20] at 6-month follow-up ( P = .47).
Conclusion
Percutaneous transpedicular fixation of VCF by PEEK implants appears feasible and safe.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Interventional Radiology, Tenon Hospital, APHP, Sorbonne Université, Paris, France.
- Department of Interventional Radiology, Gustave Roussy Hospital, Villejuif, France.
- Polyclinique Bordeaux Nord Aquitaine, Institut Européen du Dos-VERTEBRA, Bordeaux, France.
- Department of Radiology, Interventional Radiology and Neuroradiology Services, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
ORCID-Profile: Léo Razakamanantsoa, Francois H Cornelis
Förderung
- NCI NIH HHS
- NIH/NCI Cancer Center
Zitieren
APA
Barral, M., Razakamanantsoa, L., Tselikas, L., De Baere, T., Le Huec, J. C., & Cornelis, F. H. (2024). Polyetheretherketone Polymer Transpedicular Vertebral System to Treat Vertebral Compression Fracture: A Multicentre Pilot Study of Feasibility and Safety. Canadian Association of Radiologists Journal. https://doi.org/10.1177/08465371241228256
Vancouver
Barral M, Razakamanantsoa L, Tselikas L, De Baere T, Le Huec JC, Cornelis FH. Polyetheretherketone Polymer Transpedicular Vertebral System to Treat Vertebral Compression Fracture: A Multicentre Pilot Study of Feasibility and Safety. Canadian Association of Radiologists Journal. 2024. doi:10.1177/08465371241228256
BibTeX
@article{Barral2024,
author = {Barral, Matthias and Razakamanantsoa, Léo and Tselikas, Lambros and De Baere, Thierry and Le Huec, Jean-Charles and Cornelis, Francois H},
title = {Polyetheretherketone Polymer Transpedicular Vertebral System to Treat Vertebral Compression Fracture: A Multicentre Pilot Study of Feasibility and Safety},
journal = {Canadian Association of Radiologists Journal},
year = {2024},
doi = {10.1177/08465371241228256}
}
EUVIMED