Evaluation and risk communication of the effects of alcohol exposure on disposable procedure masks and portable air purifiers in hospital environments
Toxicology and Industrial Health · 2024
DOI: 10.1177/07482337241227010 ↗Kurz gefasst
Fachartikel in der Zeitschrift Toxicology and Industrial Health, 2024. Verfasst von Yo Ishigaki und 2 weiteren Autor:innen. Beteiligte Einrichtung: Research Center for Realizing Sustainable Societies, University of Electro-Communications, Tokyo, Japan. Hauptthemen laut MEDLINE: Air Filters. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 12 Literaturangaben. Gefördert von: KAKENHI grant from the Japan Society for the Promotion of Science.
Abstract (Originalsprache)
Electret technology was widely used to prevent the airborne transmission of bioaerosols during the COVID-19 pandemic and improve the filtration efficiency of masks and high-efficiency particulate air (HEPA) filters. As alcohol disinfectants are widely used in medical and welfare institutions, concerns about alcohol exposure inactivating electret exist. However, comprehensive alcohol exposure tests have not been conducted on masks and HEPA filters distributed in Japan. Twenty-five types of masks and five types of HEPA filters were subjected to a discharging process according to ISO 16890 to quantitatively elucidate the resistance to alcohol exposure. Measurements of changes in filtration efficiency and pressure drop before and after discharge show that 17 masks (68%) and four HEPA filters (80%) exhibited a significant decrease in filtration efficiency, confirming their vulnerability to alcohol. In addition, a survey ( n = 500 Japanese adults, including 30 healthcare professionals) revealed that ∼90% of the general public were unaware that alcohol exposure could degrade masks and air purifiers. Furthermore, 36% of the surveyed healthcare professionals had sprayed alcohol directly onto their masks. The effectiveness of user warnings through product labels and instructions was investigated from the perspective of ensuring the safety of patients and healthcare professionals. Results revealed that the best approach was to describe the extent and duration of the adverse effects caused by disregarding precautions. Increase in awareness of healthcare professionals and general public by authorities and manufacturers through guidelines and warning labels would reduce the risk of inhaling bioaerosols caused by unintentional electret inactivation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Research Center for Realizing Sustainable Societies, University of Electro-Communications, Tokyo, Japan.
- Info-Powered Energy System Research Center (i-PERC), University of Electro-Communications, Tokyo, Japan.
- Shinwa Corporation, Tokyo, Japan.
ORCID-Profile: Yo Ishigaki
Förderung
- KAKENHI grant from the Japan Society for the Promotion of Science
Zitieren
APA
Ishigaki, Y., Yokogawa, S., & Kato, T. (2024). Evaluation and risk communication of the effects of alcohol exposure on disposable procedure masks and portable air purifiers in hospital environments. Toxicology and Industrial Health. https://doi.org/10.1177/07482337241227010
Vancouver
Ishigaki Y, Yokogawa S, Kato T. Evaluation and risk communication of the effects of alcohol exposure on disposable procedure masks and portable air purifiers in hospital environments. Toxicology and Industrial Health. 2024. doi:10.1177/07482337241227010
BibTeX
@article{Ishigaki2024,
author = {Ishigaki, Yo and Yokogawa, Shinji and Kato, Tatsuo},
title = {Evaluation and risk communication of the effects of alcohol exposure on disposable procedure masks and portable air purifiers in hospital environments},
journal = {Toxicology and Industrial Health},
year = {2024},
doi = {10.1177/07482337241227010}
}