Compartment temperature estimation of a multiple-layer cable tray fire with different cable arrangements in a closed compartment

Xianjia Huang, Yuhong Wang, Wuyong Zeng, Lan Peng, Anthony CH Cheng, WK Chow

Journal of Fire Sciences · 2019-07 · 37 (4-6) · 303-319

DOI: 10.1177/0734904119860410 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Fire Sciences, online erschienen am 01.07.2019. Verfasst von Xianjia Huang und 5 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: guangdong provincial development and reform commission, National Key Research and Development Program of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fire hazard analysis of multiple-layer cable tray is an important part of nuclear safety analysis. Large-scale cable fire experiments with a three-layer horizontal cable tray were conducted in a closed compartment. The vertical temperature profile in the middle of the room was acquired. Distinctive stratification phenomena were found in the vertical temperature distribution. The interface between the upper and lower layer was located at approximately the height of the top cable layer. Heat transfer between the smoke and compartment walls occurred mainly above the smoke interface. A modified non-steady energy balance model in a closed compartment which included the effect of smoke interface height was used to estimate the compartment temperatures. Compared with the experimental results, the modified model for the multiple-layer cable tray fire in a closed compartment provides better estimation than the original model.

Förderung

  • guangdong provincial development and reform commission
  • National Key Research and Development Program of China

Zitieren

APA

Huang, X., Wang, Y., Zeng, W., Peng, L., Cheng, A. C., & Chow, W. (2019). Compartment temperature estimation of a multiple-layer cable tray fire with different cable arrangements in a closed compartment. Journal of Fire Sciences, 37(4-6), 303-319. https://doi.org/10.1177/0734904119860410

Vancouver

Huang X, Wang Y, Zeng W, Peng L, Cheng AC, Chow W. Compartment temperature estimation of a multiple-layer cable tray fire with different cable arrangements in a closed compartment. Journal of Fire Sciences. 2019;37(4-6):303-319. doi:10.1177/0734904119860410

BibTeX
@article{Huang2019,
  author = {Huang, Xianjia and Wang, Yuhong and Zeng, Wuyong and Peng, Lan and Cheng, Anthony CH and Chow, WK},
  title = {Compartment temperature estimation of a multiple-layer cable tray fire with different cable arrangements in a closed compartment},
  journal = {Journal of Fire Sciences},
  year = {2019},
  volume = {37},
  number = {4-6},
  pages = {303--319},
  doi = {10.1177/0734904119860410}
}