EUVIMEDEUVIMED entdecken
Crossref

Distal Biceps Tendon Repair With Interlinked Knotless All-Suture Anchors Provides Greater Footprint Optimization and Higher Fixation Security Over Intramedullary Cortical Button Repair: A Biomechanical Study

Jim C Hsu iD, Genevieve M Fraipont, Michelle H McGarry iD, Victor T Hung, Jonathan M Salandra, Gregory J Adamson, Thay Q Lee

The American Journal of Sports Medicine · 2025

DOI: 10.1177/03635465251365498 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The American Journal of Sports Medicine, 2025. Verfasst von Jim C Hsu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics & Rehabilitation, Yale School of Medicine, New Haven, Connecticut, USA. Hauptthemen laut MEDLINE: Suture Anchors, Tendon Injuries, Suture Techniques. Die Arbeit nennt 37 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Recent biomechanical investigations of distal biceps tendon repair (DBTR) constructs have typically evaluated time-zero fixation security, while tendon-bone repair footprint characterization has been limited. Consequently, interactions between repair construct design, fixation security, and repair footprint parameters remain minimally assessed. Purpose/Hypothesis: The purpose was to compare time-zero fixation security and repair footprint parameters between a new DBTR construct with 2 interlinked knotless all-suture anchors and an established DBTR construct with an intramedullary cortical button. It was hypothesized that the new interlinked twin-anchor repair technique would demonstrate greater time-zero fixation security and footprint optimization. Study Design: Controlled laboratory study.

Methods

A total of 20 cadaveric elbows in 2 matched groups underwent DBTR with either (1) twin interlinked knotless all-suture anchors or (2) a single intramedullary cortical button. Anatomic and repair footprints were digitally captured with a 3-dimensional coordinate-measuring machine. The repair constructs underwent cyclic loading and then were loaded to failure. Anatomic and repair footprint areas and their overlap, tendon-bone interface and total construct displacement, ultimate failure load, and failure mode were recorded. Anatomic footprint restoration and repair footprint accuracy were calculated.

Results

The interlinked knotless twin-anchor repair construct demonstrated a larger repair footprint area (55.1 ± 14.9 vs 35.2 ± 19.8 mm 2 , respectively; P = .032), greater anatomic footprint restoration (42.7% ± 12.9% vs 20.2% ± 9.4%, respectively; P = .003), lower tendon-bone interface displacement (3.2 ± 1.2 vs 12.4 ± 6.6 mm, respectively; P = .003), lower total construct displacement (5.5 ± 1.7 vs 13.9 ± 8.1 mm, respectively; P = .015), and higher ultimate failure load (468.3 ± 124.2 vs 313.2 ± 103.4 N, respectively; P = .001) compared with the single-button repair construct. The most common failure mode was knot slippage/suture breakage (60%) in the single-button group and suture-tendon interface failure (50%) in the twin-anchor group.

Conclusion

While this cadaveric study did not account for the effects of tendon-bone healing, the novel interlinked twin-anchor DBTR construct demonstrated greater time-zero fixation security, a larger repair footprint, and greater anatomic footprint restoration over the established single-button repair construct. Clinical Relevance: A DBTR construct with twin interlinked knotless all-suture anchors offers multiple features, including time-zero fixation security and footprint optimization, that may potentially improve clinical outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Suture AnchorsTendon InjuriesSuture TechniquesHumansBiomechanical PhenomenaCadaverMaleMiddle AgedAgedFemaleTendons

Stichwörter der Autor:innen

biomechanics of tendondistal bicepselbowtendon repair

Autor:innen und Institutionen

  • Department of Orthopaedics & Rehabilitation, Yale School of Medicine, New Haven, Connecticut, USA.
  • Orthopaedic Biomechanics Laboratory, Congress Medical Foundation, Pasadena, California, USA.
  • Orthopaedic Biomechanics Laboratory, Department of Orthopaedic Surgery, Creighton University School of Medicine, Omaha, Nebraska, USA.

ORCID-Profile: Jim C Hsu, Michelle H McGarry

Zitieren

APA

Hsu, J. C., Fraipont, G. M., McGarry, M. H., Hung, V. T., Salandra, J. M., Adamson, G. J., & Lee, T. Q. (2025). Distal Biceps Tendon Repair With Interlinked Knotless All-Suture Anchors Provides Greater Footprint Optimization and Higher Fixation Security Over Intramedullary Cortical Button Repair: A Biomechanical Study. The American Journal of Sports Medicine. https://doi.org/10.1177/03635465251365498

Vancouver

Hsu JC, Fraipont GM, McGarry MH, Hung VT, Salandra JM, Adamson GJ, et al. Distal Biceps Tendon Repair With Interlinked Knotless All-Suture Anchors Provides Greater Footprint Optimization and Higher Fixation Security Over Intramedullary Cortical Button Repair: A Biomechanical Study. The American Journal of Sports Medicine. 2025. doi:10.1177/03635465251365498

BibTeX
@article{Hsu2025,
  author = {Hsu, Jim C and Fraipont, Genevieve M and McGarry, Michelle H and Hung, Victor T and Salandra, Jonathan M and Adamson, Gregory J and Lee, Thay Q},
  title = {Distal Biceps Tendon Repair With Interlinked Knotless All-Suture Anchors Provides Greater Footprint Optimization and Higher Fixation Security Over Intramedullary Cortical Button Repair: A Biomechanical Study},
  journal = {The American Journal of Sports Medicine},
  year = {2025},
  doi = {10.1177/03635465251365498}
}
Kostenlos starten →