Biomechanical Evaluation and Surface Analysis of Glenoid Reconstruction Using a Subtalar Joint Allograft for Significant Glenoid Bone Loss in Recurrent Shoulder Instability: A Novel Alternative Graft Option
The American Journal of Sports Medicine · 2025-03 · 53 (4) · 935-943
DOI: 10.1177/03635465251315487 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The American Journal of Sports Medicine, online erschienen am 11.02.2025. Verfasst von Phob Ganokroj und 9 weiteren Autor:innen. Beteiligte Einrichtung: Steadman Philippon Research Institute, Vail, Colorado, USA. Hauptthemen laut MEDLINE: Joint Instability, Shoulder Joint, Glenoid Cavity, Bone Transplantation. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: JRF Ortho.
Abstract (Originalsprache)
Background
Glenoid and humeral head bone defects are common in chronic shoulder instability. The talus, and more specifically, the subtalar joint, has been proposed as a unique allograft from which bipolar bone loss can be addressed. However, there are few biomechanical data or joint reconstruction analyses of the glenoid using the posterior facet of a subtalar joint allograft (STA).
Purpose
To compare the contact mechanics of an STA versus a coracoid graft (Latarjet procedure) versus a distal tibial allograft (DTA) for anatomic glenoid reconstruction. Study Design: Controlled laboratory study.
Methods
A total of 8 fresh-frozen, unpaired cadaveric specimens underwent repeated-measures biomechanical testing in 5 stages: native (intact) state, bone loss (30% glenoid bone defect), Latarjet procedure, glenoid reconstruction using a DTA, and glenoid reconstruction using an STA. A compressive load of 440 N was applied to the glenohumeral joint when the humerus was mounted to a dynamic tensile testing machine in 3 shoulder positions: 30° of abduction, 60° of abduction, and 60° of abduction with 90° of external rotation (ER). Average contact pressure, contact area, and peak contact pressure were determined from the sensors. Surface area and surface congruency were calculated using a custom script. Data were analyzed using analysis of variance.
Results
There was a significantly higher surface area with glenoid reconstruction using the DTA (859 ± 78 mm 2 ; P = .005) than with glenoid reconstruction using the STA (806 ± 88 mm 2 ; P < .001) and the Latarjet procedure (692 ± 91 mm 2 ). Surface congruency was significantly better with reconstruction using the DTA (2.0 ± 0.3 mm; P = .003) or the STA (1.9 ± 0.3 mm; P = .004) than with the Latarjet procedure (2.6 ± 0.4 mm). In all shoulder positions, the average contact pressure in the bone loss state was significantly higher than that in the native state ( P < .05). All repair states restored average contact pressure to the native state at 60° of abduction and 60° of abduction with 90° of ER. There was less contact area after the Latarjet procedure than in the native state at 30° and 60° of abduction ( P = .009 and P = .040, respectively). There was no significant difference in contact area and peak contact pressure after reconstruction with the DTA or STA compared with the native state.
Conclusion
Anatomic glenoid reconstruction using a DTA or STA restored average contact pressure, peak contact pressure, and contact area at 60° of abduction and 60° of abduction with 90° of ER in a cadaveric model. In addition, surface congruency and surface area improved over the traditional Latarjet procedure. Clinical Relevance: The STA showed comparable contact mechanics and surface geometry to the DTA. Further research is needed to determine the in vivo clinical outcomes of this new alternative graft.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Steadman Philippon Research Institute, Vail, Colorado, USA.
- Siriraj Hospital, Faculty of Medicine, Mahidol University, Bangkok, Thailand.
- Department of Medical and Surgical Specialties, Radiological Sciences, and Public Health, University of Brescia, Brescia, Italy.
- Department of Orthopaedic Surgery, Brooke Army Medical Center, Fort Sam Houston, Texas, USA.
- Department of Sports Orthopaedics, Rechts der Isar Hospital, Technical University of Munich, Munich, Germany.
- The Steadman Clinic, Vail, Colorado, USA.
Förderung
- JRF Ortho
Zitieren
APA
Ganokroj, P., Hollenbeck, J. F. M., Adriani, M., Whalen, R. J., Drumm, A. H., Garcia, A. R., Buchalter, W. H., McBride, T. J., Rupp, M. C., & Provencher, M. T. (2025). Biomechanical Evaluation and Surface Analysis of Glenoid Reconstruction Using a Subtalar Joint Allograft for Significant Glenoid Bone Loss in Recurrent Shoulder Instability: A Novel Alternative Graft Option. The American Journal of Sports Medicine, 53(4), 935-943. https://doi.org/10.1177/03635465251315487
Vancouver
Ganokroj P, Hollenbeck JFM, Adriani M, Whalen RJ, Drumm AH, Garcia AR, et al. Biomechanical Evaluation and Surface Analysis of Glenoid Reconstruction Using a Subtalar Joint Allograft for Significant Glenoid Bone Loss in Recurrent Shoulder Instability: A Novel Alternative Graft Option. The American Journal of Sports Medicine. 2025;53(4):935-943. doi:10.1177/03635465251315487
BibTeX
@article{Ganokroj2025,
author = {Ganokroj, Phob and Hollenbeck, Justin F M and Adriani, Marco and Whalen, Ryan J and Drumm, Amelia H and Garcia, Alexander R and Buchalter, Wyatt H and McBride, Trevor J and Rupp, Marco-Christopher and Provencher, Matthew T},
title = {Biomechanical Evaluation and Surface Analysis of Glenoid Reconstruction Using a Subtalar Joint Allograft for Significant Glenoid Bone Loss in Recurrent Shoulder Instability: A Novel Alternative Graft Option},
journal = {The American Journal of Sports Medicine},
year = {2025},
volume = {53},
number = {4},
pages = {935--943},
doi = {10.1177/03635465251315487}
}