EUVIMEDEUVIMED entdecken
Crossref

The Effect of Varying Sizes of Ramp Lesions in the ACL-Deficient and Reconstructed Knee: A Biomechanical Robotic Investigation

Adrian Deichsel iD, Henrike Miets, Christian Peez, Michael J Raschke, Matthias Klimek, Johannes Glasbrenner, Elmar Herbst, Christoph Kittl

The American Journal of Sports Medicine · 2024-03 · 52 (4) · 928-935

DOI: 10.1177/03635465231223686 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The American Journal of Sports Medicine, online erschienen am 11.02.2024. Verfasst von Adrian Deichsel und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Anterior Cruciate Ligament Injuries, Joint Instability. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 59 Literaturangaben. Gefördert von: Society for Arthroscopy and Joint Surgery.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Conflicting evidence has been reported regarding the biomechanical relevance of ramp lesions (RLs) on knee kinematics. Furthermore, the influence of the defect size of the RLs on anterior tibial translation (ATT) and external rotation (ER) is currently unknown.

Purpose

To evaluate the influence of RL defect size on knee kinematics in anterior cruciate ligament (ACL) deficiency and after simulated ACL reconstruction (sACLR). Study Design: Controlled laboratory study.

Methods

Eight cadaveric knee specimens were tested in a 6 degrees of freedom robotic test setup. Force-controlled clinical laxity tests were performed with 200 N of axial compression in 0°, 30°, 60°, and 90° of flexion: 5 N·m internal rotation (IR)/ER torque, 134 N ATT force, and an anteromedial drawer test consisting of 134 N ATT force under 5 N·m ER torque. After determining the native knee kinematics, the ACL was cut at the tibial insertion, followed by a transosseous refixation to simulate a surgical repair or reconstruction (simulated ACL reconstruction; sACLR). An RL was sequentially created with a length of 1, 2, and 3 cm. Each state of the RL was evaluated in the ACL-deficient state and after sACLR.

Results

In the ACL-deficient state, only an RL of 3 cm length resulted in a significant increase of ATT in 30° of flexion (mean difference 0.73 mm; 95% CI, 0.36-1.1 mm). After sACLR, an RL had no significant effect. When looking at ER, an RL significantly increased ER in full extension in the ACL-deficient state in 2 cm (mean difference 0.9°; 95% CI, 0.08°-1.74°) and 3 cm length (mean difference 1.9°; 95% CI, 0.57-3.25). Furthermore, a 3-cm RL significantly increased IR in 0° of flexion in the ACL-deficient state (mean difference 1.9°; 95% CI, 0.2°-3.6°). No effect of ramp lesions on rotation was found after sACLR.

Conclusion

RLs result in a small increase in ATT, ER, and IR in ACL-deficient knees at early flexion angles, but not after sACLR. Clinical Relevance: Small RLs did not change time-zero knee kinematics and may, therefore, be left untreated, especially when the ACL is reconstructed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresAnterior Cruciate Ligament InjuriesJoint InstabilityHumansAnterior Cruciate LigamentCadaverKnee JointRange of Motion, ArticularBiomechanical Phenomena

Stichwörter der Autor:innen

anterior cruciate ligamentbiomechanicskneeligamentsramp lesionsreconstruction

Autor:innen und Institutionen

  • Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany.

ORCID-Profile: Adrian Deichsel

Förderung

  • Society for Arthroscopy and Joint Surgery

Zitieren

APA

Deichsel, A., Miets, H., Peez, C., Raschke, M. J., Klimek, M., Glasbrenner, J., Herbst, E., & Kittl, C. (2024). The Effect of Varying Sizes of Ramp Lesions in the ACL-Deficient and Reconstructed Knee: A Biomechanical Robotic Investigation. The American Journal of Sports Medicine, 52(4), 928-935. https://doi.org/10.1177/03635465231223686

Vancouver

Deichsel A, Miets H, Peez C, Raschke MJ, Klimek M, Glasbrenner J, et al. The Effect of Varying Sizes of Ramp Lesions in the ACL-Deficient and Reconstructed Knee: A Biomechanical Robotic Investigation. The American Journal of Sports Medicine. 2024;52(4):928-935. doi:10.1177/03635465231223686

BibTeX
@article{Deichsel2024,
  author = {Deichsel, Adrian and Miets, Henrike and Peez, Christian and Raschke, Michael J and Klimek, Matthias and Glasbrenner, Johannes and Herbst, Elmar and Kittl, Christoph},
  title = {The Effect of Varying Sizes of Ramp Lesions in the ACL-Deficient and Reconstructed Knee: A Biomechanical Robotic Investigation},
  journal = {The American Journal of Sports Medicine},
  year = {2024},
  volume = {52},
  number = {4},
  pages = {928--935},
  doi = {10.1177/03635465231223686}
}
Kostenlos starten →